Installation of outdoor unit

Step one: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
● Take sufficient protective measurements
when installing outdoor unit.
● Make sure the support can withstand at
least four times of the unit weight.
● The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are
needed.
Step two: install drain joint
(Only for cooling and heating
unit)
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the
drain vent.
drain vent
Drain hose
chassis
outdoor drain joint
at least 3cm above the floor
Step three: fix outdoor unit
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
12
foot holes
foot holes

Hide quick links: