Wiring - Daikin FTXV25AV1B Owner's Manual

R410a split series
Hide thumbs Also See for FTXV25AV1B:
Table of Contents

Advertisement

Wiring

● Do not turn ON the safety breaker until all work is completed.
1) For both outdoor and indoor units, strip the insulation from the
wire (40mm).
2) Connect the connection wires between the indoor and outdoor units
so that the terminal numbers match. Tighten the terminal screws
securely. We recommend a flathead screw driver be used to tighten
the screws.
3) For connecting outdoor unit to indoor unit use standardized supply
cable H05RN.
Firmly fix the wires with
the terminal screws.
When wire length exceeds 10m,
use 2.0mm diameter wires.
1
Outdoor
2
3
unit
Firmly fix the wires with
the terminal screws.
Indoor unit
1 2 3
Safety
Earth leakage
breaker
circuit breaker
H05RN
Earth
32
Power supply
50Hz 220-240V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents