Fuel Conversion Procedure
Refer to fig. 47, Illustrated Parts Breakdown, to identify part
numbers below.
1.
Turn off gas supply to stove.
2. Remove the stove Top Plate (41).
3.
Disengage the two Glass Frame Latches at the top of
the firebox. See illustration on page 5. Carefully lift the
glass panel up and out of the stove.
4. If installed, remove the Embers and Log Set using care
not to damage the fragile log parts.
5.
Lift out the Burner Skirt (33). Tilt the skirt at an angle
to clear the firebox sides and front.
6. Reach under the stove and remove the Air Shutter
wingnut from its stud. As you face the right side, it is
the one closest to you. See fig. 21.
7.
Lift out the Burner Plate: NOTE: There are no screws
securing the Burner to the floor of the firebox. Pull the
Air Shutter forward and lift the burner together with
shutter up and out of the stove as a unit. See fig. 22.
8. Change the Main Burner Orifice. See fig. 23. Using a
1/2" open ended wrench or deep-well socket remove
the burner orifice from its brass elbow housing and
replace with the appropriate orifice supplied in the kit.
#33 for NG
1.65 mm for LP
9. Replace the Air Shutter with its gasket and push it all
the way back to allow replacement of the Burner Plate.
10. Replace the Burner Plate. Engage the Air Inlet Tube
with the Air Shutter and burner orifice. Properly
seated, the burner plate will be engaged at its front
corners with the two support brackets located at the
front of the firebox.
• Replace the wingnut loosely on the air shutter stem
under the stove. Air shutter adjustment will be done
last.
11. CHANGE THE PILOT ORIFICE: From within the firebox,
remove the Pilot Head by pulling it straight up from
the pilot base. See fig. 25.
Using the 4 mm allen wrench that is included with the
conversion kit, unscrew the pilot orifice (counterclock-
wise). Replace with the appropriate orifice:
# 51 for natural gas
#30 for propane gas
12. Tighten orifice into the base of the pilot assembly.
To prevent bypass leaks, be sure the orifice is secured
tightly and flush with the base. Replace pilot head by
pushing it down onto the pilot base.
13. Replace the Variable Regulator. Using a Torx T-20 screw-
driver, remove the three screws from the front of the
valve regulator. See fig. 26.
Air
Shutter
OPEN
Wingnut
FRONT
LEG
Figure 21. Locate and remove the Air Shutter wingnut
from under the right side of the stove.
Air Shutter
Burner Plate
Figure 22. Remove the Air Shutter and Burner as a unit.
Burner
Orifice
Figure 23. Change the Burner Orifice.
Opening
Dimension
Figure 24. Air Shutter Setting
137750_Rev_L 11.16.12
CLOSED
BACK
LEG
Brass Elbow
Air Shutter
Air Inlet
Tube
Burner Plate
17