Intertek Jotul GF 400 DV Sebago Installation And Operation Instructions Manual page 10

Direct vent gas stove
Table of Contents

Advertisement

137750_Rev_L 11.16.12
Vent Termination Zones - Natural Gas
35 Ft.
(10.67 m)
30 Ft.
(9.14 m)
25 Ft.
(7.62 m)
A
20 Ft.
(6.10 m)
15 Ft.
(4.57 m)
12 Ft.
(3.65 m)
B
Min. Vertical
8 Ft.
Termination
(2.43 m)
5 Ft.
(1.52 m)
Min. Rise
2 Ft.
(.60 m)
(1.52 m)
F400 Coaxial Vent Window - NG
• ALL VENTING MUST TERMINATE (END) WITHIN ONE OF
THE SHADED AREAS.
• SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT
CORRESPONDS TO THE VENT TERMINATION AREA IN THE
DIAGRAM ABOVE.
• ALWAYS MAINTAIN THE PROPER CLEARANCES TO COM-
BUSTIBLES.
The circled letter designations in the vent diagram correspond
to the Exhaust Restrictor Setting on the stove. First, determine
which vent termination zone is appropriate for your installation
and fuel type, then adjust the restrictor to the corresponding
position as shown in Figure 7, page 9.
Figure 9. Coaxial Vent Termination Window / NG
10
Horizontal and Vertical
Terminations for COAXIAL VENT
Up to four 45° or
two 90° elbows
addition to the
starter elbow.
A
B
C
5 Ft.
10 Ft.
15 Ft.
(3.05 m)
(4.57 m)
HORIZONTAL RUN
permitted in
D
20 Ft.
27 Ft.
(6.09 m)
(8.22m)
Vertical
Termination for
COLINEAR VENT
35 Ft.
35 Ft.
(10.67 m)
(10.67 m)
25 Ft.
25 Ft.
(7.62 m)
(7.62 m)
B
Minimum
Minimum
Vertical
Vertical
Termination
Termination
8 Ft.
8 Ft.
(2.43 m)
(2.43 m)
45°
Elbow
Up
2 Ft.
2 Ft.
(16 cm)
(16 cm)
HORIZONTAL RUN
• VENTING MUST TERMI-
NATE (END) WITHIN THE
SHADED AREA.
• Adjust the Exhaust Re-
strictor to position B for
any NG colinear termi-
nation.
Figure 10 . Colinear Termination / NG

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents