<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
>>KEY SOUND

BUZZER

REMAIN HDD

CALL OUT SETTINGS
EMERGENCY REC DURATION
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } Select "KEY SOUND" in the <REAR
TERMINAL SETTINGS> screen. Display the desired setting
and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
BUZZER
It is possible for a buzzer to sound when the remaining
HDD device or archive device space reaches the value
set in "REMAIN HDD" of the <REAR TERMINAL SET-
TINGS> screen. Other than the above, it is possible to
set the buzzer to sound when starting alarm recording
or emergency recording, or when a warning is displayed.
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5

KEY SOUND

>>BUZZER
REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
To sound a buzzer only when reaching a specified value :
1) Select "REMAIN" for "BUZZER" in the <REAR TER-
MINAL SETTINGS> screen.
2) Set the remaining capacity in "REMAIN HDD" of the
<REAR TERMINAL SETTINGS> screen.
To sound a buzzer when reaching the set remaining
capacity or when a warning is displayed :
1) Select "WARNING" for "BUZZER" in the <REAR TER-
MINAL SETTINGS> screen.
2) Set the remaining HDD capacity (HDD MAIN RE-
MAIN/HDD SUB REMAIN/ARCHIVE REMAIN) in "CALL
OUT SETTINGS" of the <REAR TERMINAL SET-
TINGS> screen.
Setting ( default : "OFF" )
"REMAIN", "WARNING", "ALARM", "OFF"
SETTING
BUZZER
When reaching the remaining
capacity set in "REMAIN HDD"
When a failure occurs and
a warning is displayed
When an alarm recording or
emergency recording is started
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
REMAIN
WARNING
ALARM
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
1. Press the SET UP button } <SETTINGS> } <INITIAL SET UP/
INFORMATION> } Select "BUZZER" in the <REAR TERMINAL
SETTINGS> screen. Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
REMAIN HDD
A warning indicating that either remaining capacity of
HDD or archive device has become full during record-
ing is outputted.
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
KEY SOUND
BUZZER
>>REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
A warning is outputted using the following methods
when the remaining capacity becomes low during re-
cording.
• The HDD usage display flashes when "3" is set to
"DISPLAY MODE" in the <TIME DATE/DISPLAY SET-
TINGS> screen.
• A buzzer will sound when "REMAIN" is set to "BUZZER"
in the <REAR TERMINAL SETTINGS> screen.
Setting of DEVICE ( default : "MAIN" )
"MAIN" : Displays a warning of low MAIN HDD capacity.
"SUB" : Displays a warning of low SUB HDD capacity.
"ARCHIVE" : Displays a warning of low archive device
capacity.
"OFF" : Does not display warning of low capacity.
"SUB" appears when "PARTITION" is selected on
"HDD SETTING" of the <INITIALIZATION> screen.
Setting of "REMAIN HDD" ( default : "10%" )
"2%", "4%", "6%", "8%", "10%", "15%","20%", "30%",
"40%", "50%"
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } "Select "REMAIN HDD" in the <REAR
TERMINAL SETTINGS> screen and turn the SHUTTLE ring
clockwise twice.
• The setting display reverses in color when the SHUTTLE
ring is turned the first time. When the ring is turned for the
second time, the background turns red and flashes.
2. Turn the JOG dial to display the desired device and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
3. Turn the JOG dial clockwise to move the reversed display to
the REMAIN HDD value and turn the SHUTTLE ring clockwise.
• The background of the REMAIN HDD value turns red and flashes.
4. Turn the JOG dial to display the desired capacity and turn
the SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
5. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
57
57

Advertisement

Table of Contents
loading

Table of Contents