Major operations and their functions (continued)
Rear View (continued)
1
ON
MAIN
OFF
~
AC IN
7
REC terminal
Input terminal to start recording. Not available dur-
ing timer recording.
EMERGENCY terminal
Input terminal initiating EMERGENCY recording
mode.
MODE OUT 1 ~ MODE OUT 5 terminals
Output terminal to indicate the unit's current mode.
Select the unit's condition by MODE OUT 1 ~ MODE
OUT 5 setting in the <REAR TERMINAL SETTINGS>
menu.
CALL OUT terminal / CALL OUT GND terminals
This is the ISOLATION output terminal. Information
that can be transmitted externally consists of CALL
OUT settings made on the <REAR TERMINAL SET-
TINGS> menu screen as well as fixed output set-
tings.
DC 5V OUT terminal
Will only output when both the MAIN switch and
POWER button are ON. The maximum electric cur-
rent is 30mA.
14. RS-232C connector
This connector is used to connect to host device with
RS-232C connector. This unit can be controlled by
another device through this connector.

15. ETHERNET connector

Use a 10BASE-T cable to connect to the Ethernet
terminal. Please use the cable adapted to
10BASE-T. DUPLEX MODE is HALF DUPLEX.
RECEIVE indicator
Illuminates when the unit is receiving a signal via the
ethernet connection.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
18
2 3
IN
1
2
3
4
5
OUT
OUTPUT A OUTPUT B
VIDEO
Y/C
REMOTE
RESET
RS-485/
RS-422
8
9
10
11
4
CAMERA
6
7
8
9
10
11
GND
ALARM IN
RS-232C
12
13
14
SEND indicator
Illuminates when the unit is transmitting a signal via
the ethernet connection.
16. SCSI connector
This connector is used to connect to peripheral re-
cording device (CD-R/RW, tape and HDD's).
6
5
IN
12
13
14
15
16
OUT
AUDIO
MIC
OUT
IN
ETHERNET
SCSI
RECEIVE
SEND