Call Out Settings; Key Sound; Buzzer - Mitsubishi Electric DX-TL5000U Installer Manual

Digital recorder
Hide thumbs Also See for DX-TL5000U:
Table of Contents

Advertisement

• "Main-Alarm" appears when "Alarm Recording Area"
(System Menu Memory Data Management Setting
for Main Memory Change Partition Setting) is set to
other than "0 %."
• "Main-LPA" appears when "Long Pre-Alarm Area"
(System Menu Memory Data Management Setting
for Main Memory Change Partition Setting) is set to
other than "0 %."
3. Set the desired capacity.
step
• Set the remaining capacity of each device to
output signal.

Call Out Settings

This item is used to output warning signals from the CALL
OUT terminal to the device connected when the capacity
becomes full or reaches to the specified value.
Setup Menu
4
System
Rear Terminal Setting
3
2
1. Set the desired capacity for each area.
step
Off: Does not output a signal.
• "Alarm Recording Area" can be set when "Alarm
Recording Area" (System Menu Memory Data
Management Setting for Main Memory Change
Partition Setting) is set to other than "0 %."
• "LPA Recording Area" can be set when "Long Pre-
Alarm Area" (System Menu Memory Data
Management Setting for Main Memory Change
Partition Setting) is set to other than "0 %."
• Call out settings use the photo-coupler output to
decrease the malfunctions due to wiring. See CALL
OUT signal output (
connection.
• For the relationship between the warning display and
CALL OUT signal output,
The warning display of the item written "Fixed" in the
CALL OUT output column displays unconditionally.
For the item written "Selectable" in the CALL OUT
output column, you can set the condition that CALL
OUT signal is output. For example, the buzzer can
be set to sound when reaching the value set in
"Normal Recording Area," "Alarm Recording Area,"
"LPA Recording Area," or "Copy 2" (Setup
Menu System Rear Terminal Setting Call Out
Settings) when "Buzzer" (Setup Menu System Rear
Terminal Setting) is set to "Warning."
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
Call Out Settings
see page 18) for the correct
see pages 114 and 115.

Key Sound

This item is used to make a sound when using the opera-
tional buttons, JOG dial, and SHUTTLE ring.
Setup Menu
4
System
Rear Terminal Setting
3
1. Set the key sound to on or off.
step

Buzzer

This item is used for a buzzer to sound when the remain-
ing main or copy 2 device capacity reaches the value set in
"Low Memory Alarm Setting" (Setup Menu System Rear
Terminal Setting Mode Out Settings). Other than the
above, it is possible to set the buzzer to sound when start-
ing alarm recording or emergency recording, or when a
warning is displayed.
To sound a buzzer only when reaching a specified remain-
ing HDD capacity:
1) Set "Buzzer" to "Remain."
2) Set the remaining capacity in "Low Memory Alarm Set-
ting"
(Setup
Menu System Rear
Setting Mode Out Settings).
To sound a buzzer when reaching the specified remaining
HDD capacity and when a warning is displayed:
1) Set "Buzzer" to "Warning."
2) Set the remaining HDD capacity in the "Call Out Set-
tings." (Setup Menu System Rear Terminal
Setting Call Out Settings ).
Setup Menu
4
System
3
Rear Terminal Setting
1. Set the desired buzzer setting.
step
SETTING
Remain
BUZZER
When reaching the remaining
ON
capacity set in "Low Memory
Alarm Setting"
When a failure occurs and
OFF
a warning is displayed
When an alarm recording or
OFF
emergency recording is started
When controlling the buzzer to be
OFF
sound via the personal computer
Terminal
Warning
Alarm
LAN
Off
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
61