Rear Terminal Settings; Mode Out 1 To Mode Out 5; Key Sound; Buzzer - Mitsubishi Electric DX-NT400E Installation And Operation Manual

Mitsubishi dvr installation and operation manual dx-nt400e
Hide thumbs Also See for DX-NT400E:
Table of Contents

Advertisement

REAR TERMINAL SETTINGS

MODE OUT 1 to MODE OUT 5

These items are used to output the status of this unit from
the MODE OUT terminals on the rear panel. There are 5
MODE OUT terminals. Set output type for each terminal
individually.
<REAR TERMINAL SETTINGS>
>>MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5

KEY SOUND

BUZZER

REMAIN HDD
CALL OUT SETTINGS
EMERGENCY REC DURATION
Setting (default: "OFF")
"REC": Outputs signals during recording.
"PLAY": Outputs signals during playback.
"REMAIN": Outputs signals when the remaining HDD
capacity reaches the value specified in "REMAIN
HDD."
"POWER": Outputs signals when the power of the
unit turns on.
"MOTION1" to "MOTION4": Outputs the signal from
the specified MODE OUT terminal when detecting
motion by a specified camera number. For example,
when you set MODE OUT 1 to MOTION 1, the signal
is output from the MODE OUT 1 terminal when
detecting motion by the camera number 1.
Furthermore, the last input of the motion detection
maintained for 2 seconds.
"ALARM": Outputs signals during alarm recording.
"LAN": Controls ON/OFF of the terminal set to this
item via PC by using the specified application.
"CALL OUT": Outputs CALL OUT signal when the
error occurs to the unit. Refer to the table on page
81.
"OFF": Does not output signal.
Remaining warning from MODE OUT is output
only during recording.
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } Select "REAR TERMINAL SETTINGS"
screen.
2. For the desired terminal (from MODE OUT 1 to MODE
OUT 5), display the desired setting and then determine such
setting.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
3. To set other terminals, repeat step 2.
4. Press the CLEAR button or the SET UP button.
KEY SOUND
This item is used to make button sounds when using the
operational buttons.
OFF
OFF
OFF
OFF
OFF
ON
OFF
MAIN-10%
10M
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } Select "KEY SOUND" in the <REAR
TERMINAL SETTINGS> screen. Display the desired setting
and determine such setting.
2. Press the CLEAR button or the SET UP button.
BUZZER
This item is used for a buzzer to sound when the remain-
ing HDD capacity reaches the value set in "REMAIN HDD"
of the <REAR TERMINAL SETTINGS> screen. Other than
the above, it is possible to set the buzzer to sound when
starting alarm recording or emergency recording, or when
a warning is displayed.
To sound a buzzer only when reaching a specified remaining
HDD capacity:
1) Select "REMAIN" for "BUZZER" in the <REAR TERMI-
NAL SETTINGS> screen.
2) Set the remaining capacity in "REMAIN HDD" of the
<REAR TERMINAL SETTINGS> screen.
To sound a buzzer when reaching the specified remaining
HDD capacity and when a warning is displayed:
1) Select "WARNING" for "BUZZER" in the <REAR TER-
MINAL SETTINGS> screen.
2) Set the remaining HDD capacity (HDD MAIN REMAIN/
HDD SUB REMAIN) in "CALL OUT SETTINGS" of the
<REAR TERMINAL SETTINGS> screen.
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
>>KEY SOUND
BUZZER
REMAIN HDD
MAIN-10%
CALL OUT SETTINGS
EMERGENCY REC DURATION
<REAR TERMINAL SETTINGS>
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
MODE OUT 5
KEY SOUND
>>BUZZER
REMAIN HDD
MAIN-10%
CALL OUT SETTINGS
EMERGENCY REC DURATION
OFF
OFF
OFF
OFF
OFF
ON
OFF
10M
OFF
OFF
OFF
OFF
OFF
ON
OFF
10M
49