<RECORD SETTINGS> (continued)
<RECORD SETTING> 1/2
Camera selection during alarm recording
<RECORD SETTING>
NO
PPS
1
1.875P STD
2
1.875P STD
3
1.875P STD
4
1.875P STD
5
1.875P STD
6
1.875P STD
7
1.875P STD
8
1.875P STD
9
1.875P STD
NEXT PAGE
<RECORD SETTING> 2/2
<RECORD SETTING>
NO
PPS
10
>>
1.875P STD
11
1.875P STD
12
1.875P STD
13
1.875P STD
14
1.875P STD
15
1.875P STD
16
1.875P STD

PRE ALARM REC

<ESTD REC>
Appears when "PARTITION" is set.
CAUTION : For <ESTD REC>,
"Continuous recording time table", pages 92, 93.
The storage area in MAIN HDD set in "PARTI-
TION" is displayed with the percentage(%) and the
recordable time of that storage area is displayed in
"<ESTD REC>".
The <RECORD SETTING> screen consists of 2
pages. The second page is displayed by turning the
JOG dial moving the cursor to "NEXT PAGE", and
turn the SHUTTLE ring clockwise.
9. Turn the JOG dial and move the cursor to camera selection
item for alarm recording and turn the SHUTTLE ring clockwise.
• The background of setting turns red and flashes.
• Setting ( default : "ALARM" )
"ALARM" : Alarm recording is performed for only the cameras
set for alarm recording and inputted with alarm signals. When
there is input of alarm signals from multiple cameras, alarm
recording is performed for all cameras containing alarm signals.
"ALARM PLUS" : Recording is performed in the frame speed
set in "A-PPS" for the camera inputted with alarm signals
during normal recording. All other cameras will be recording
in the normal frame intervals.
10. Display the desired item to set and turn the SHUTTLE
ring clockwise.
• The setting is confirmed and flashing stops.
11. (When setting the recording intervals and recording picture
quality for normal recording • • • )
Turn the JOG dial to select the desired camera number and
turn the SHUTTLE ring clockwise twice.
• The background of the "PPS" display changes to red and flashes.
• Setting of "PPS" ( default : "1.875P" )
"3.75P", "1.875P", "1.25P", "0.938P", "0.75P", "0.625P",
"0.375P", "0.25P", "0.125P", "0.063P", "0.031P", "0.016P", "-
- - - - -"
"- - - - - -" : Recording cannot be performed with camera set
to this setting.
Pressing the WARNING RESET button while the
cursor is on the left of the desired camera number
changes that camera's "PPS" and "A-PPS" to "- - - - - -".
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
48
>>ALARM
GRADE A-PPS
A-GRADE
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
SHUTTLE<<:BACK
ALARM
GRADE A-PPS
A-GRADE
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
1.875P STD
( S )
S
SHUTTLE<<:BACK
%
D
H
M
see
For details concerning normal recording settings,
see "Setting the recording interval and recording
picture quality for normal recording" pages 27, 28.
12. Display the desired item to set and turn the SHUTTLE
ring clockwise.
• The setting is confirmed and flashing stops.
13. Turn the JOG dial clockwise to reverse display the
"GRADE" setting and turn the SHUTTLE ring clockwise.
• The background of the "GRADE" display changes to red
and flashes.
• Setting of "GRADE" ( default : "STD" )
"SUPER", "HIGH", "STD"(STANDARD), "BASIC", "LONG"
14. Display the desired item to set and turn the SHUTTLE
ring clockwise.
• The setting is confirmed and flashing stops.
15. (When setting recording intervals and recording picture
quality for alarm recording • • • )
Repeat steps 11 ~ 14 and select desired settings for "A-PPS"
and "A-GRADE" as well.
16. When the setting is complete, turn the SHUTTLE ring
counterclockwise.
• The cursor moves to the camera number directly to the left.
17. When continuing with other camera number, turn the JOG
dial to move the cursor to the desired camera number and
repeat steps 11 ~ 16 for settings.
18. When done with all settings, turn the SHUTTLE ring
counterclockwise or press the SET UP button to exit.
10
11
PRE ALARM REC
12
13
The pre-alarm recording can be set.
14
15
16
1.563P STD
PRE ALARM REC
<ESTD REC>
Setting ( default : "0S" )
"0S", "1S", "2S", • • • • • ,"58S", "59S", "60S", "90S",
"120S", "150S", "180S"
When "0S" is selected, the pre-alarm recording
is inoperable.
The maximum pre-alarm recordable time is dis-
played in "( )". Beware that when you set the pre-
alarm recording time longer than the maximum, the
settings will turn red. Set the time within the record-
ing time limit, so that the display returns to white. (If
the time is set beyond the limit, Pre-Alarm record-
ing time is not changed.)
1. Press the SET UP button } <SETTINGS> } <RECORD
SETTINGS> } Select "PRE ALARM REC" in the <RECORD
SETTING> 2/2 screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
1.563P STD
( S )
S
SHUTTLE<<:BACK
D
H
M

Advertisement