3.3 Changing the IP Addresses of the iQ PLC Built-in Ethernet Port

The following are steps to change the IP address of the iQ PLC Built-in Ethernet Port:
1. Open the GX Works2 on the Configuration PC and create a new project for the appropriate CPU
Module (e.g. Q13UDEH in this example).
2. Select the PLC Parameter on the Project Tree which will open the "Q Parameter Setting" window.
Then select the "Built-in Ethernet Port Setting" tab.
a. Configure the IP address, Subnet Mask and Default Router IP address to the desired
settings.
b. Change the IP address to the desired address and then select the Enable Online Change
(FTP, MC Protocol) Check box.