Warnings and CALL OUT output

Warnings and their appropriate countermeasures

#1 Options in the CALL OUT output column:
• Selectable : selects to output CALL OUT signal or not on the menu screen.
• Fixed
: outputs CALL OUT signal from the CALL OUT terminal regardless of the menu setting.
• None
: does not output CALL OUT signal, but displays a warning on the screen.
CALL OUT signal output can be stopped by pressing the WARNING RESET button.
Warning Display
REC/FULL
• MAIN HDD recordable
capacity is full.
REC/SUB FULL
• SUB HDD recordable
capacity is full.
REC/REM
• The remaining HDD
capacity has reached the
value set in HDD REMAIN.
NO SIGNAL
• Video signal was lost for
more than 5 seconds
(The warning indicates
during recording.
the number of the
non-functioning
camera. )
• Video data that has been
IMAGE MODIFIED
altered was played back.
SYSTEM ERROR
• System error has
REC/
occurred.
SYSTEM ERROR
PLAY/
SYSTEM ERROR
REC/RW
• Error has occurred during
writing of data to HDD.
MIRROR
• One HDD could not be
detected during mirroring.
<DEVICE ERROR>
• Unable to recognize
HDD.
• HDD or HDD tray is
connected or attached
incorrectly.
TEMP
• Issued when in a high
temperature environment
within the tolerance level.
FAN
• The fan stops.
(NONE)
• Reboots by watchdog
operation.
#2 : (The following numbers are in
00 : A (MASTER)
01 : B (SLAVE)
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Warnings and CALL OUT output
Countermeasure
Status
• When the warning is
cancelled, the unit starts
over-writing the oldest data
remaining in the hard disk
drive.
• Replace with new HDD.
• Replace with new HDD.
• Check whether the unit
and camera are properly
connected, and that electri
-city is on.
• Check whether the video
signal is being properly
output.
• Check that whether there
is a camera set for operation
with no video signal input.
• Reboot.
• Check the HDD.
• Check the HDD.
• Reboot.
• Reboot.
• Check that the HDD or
HDD tray is connected or
attached correctly.
• Turn off the power and
change the installation
condition.
• Turn off the power and
stop usage.
)
#3 : (The following numbers are in
01 : CAMERA IN 1
03 : CAMERA IN 3
Canceling
Code
the warning
Press and hold
WNG1100
the WARNING
RESET button.
WNG1101
Press and hold
WNG1200
the WARNING
(MAIN)
RESET button.
WNG1201
(SUB)
Stop recording.
WNG54
#3
Output video
signals.
Press and hold
the WARNING
RESET button.
Press and hold
WNG5500
the WARNING
RESET button.
Press and hold
WNG5100
the WARNING
WNG14
#2
RESET button.
WNG24
#2
Press and hold
WNG13
#2
the WARNING
RESET button.
Press and hold
WNG6100
the WARNING
RESET button.
Turn off the
WNG6200
power.
Press and hold
WNG5200
the WARNING
RESET button.
Lower
the temperature.
Press and hold
WNG5300
the WARNING
RESET button.
Rotate the fan.
WNG5101
)
02 : CAMERA IN 2
04 : CAMERA IN 4
CALL OUT
page
output
#1
Selectable
47
14-17
Selectable
14-17
Fixed
12
37
25, 26
41-43
Fixed when
47, 48
setting is
"ON"
Fixed
-
None
-
Fixed
54, 55
69
Fixed
54, 55
14-17
None
-
Fixed
-
-
81