Removal and Replacement Procedures
Removing the Drive in Drive Bay 2
To remove a hard drive from bay 2:
1. Power down the server. Refer to "Powering Down the Server" ea rlier in this chapter.
2. Extend the server from the rack. Refer to "Extending the Server from the Rack" earlier in
this chapter.
3. Remove the access panel. Refer to "R emoving the Access Panel" earlier in this chapter.
4. Remove the DVD drive or media bay blank. For more information, refer to the "DVD
Drive" section earlier in this chapter.
5. Remove the drive tray screw.
6. Disconnect the cables from the drive. You may need to slide the drive tray forward to
gain access to the cables.
7. Remove the drive tray from bay 2.
Figure 2-15: Removing the drive tray
2-16
HP CONFIDENTIAL Codename: eliXir Part Number: 361543-001 Last Saved On: 3/11/04 3:21 PM
HP ProLiant DL145 Server Maintenance and Service Guide