Symptom
Cause
Image is
One or more toner cartridges
blurred;
may be defective.
background
The OPC drum may be mis-
is lightly
installed or defective.
stained;
The fuser oil may be
there is insuf-
depleted.
ficient gloss
of the printed
image.
Background
The toner cartridge is
is foggy.
defective.
The OPC drum cartridge is
damaged.
Entire sheet
The toner cartridge is
is printed in
defective.
black or
The OPC drum cartridge is
color.
damaged.
114
Solution
Check the toner cartridges. If necessary, replace them.
Reinstall the OPC drum cartridge. If necessary, replace the
entire drum kit.
Check the fuser oil condition. If necessary, replace it.
Remove the toner cartridge and check for damage.
If necessary, replace it.
Remove the OPC drum cartridge and check for damage.
If necessary, replace the entire drum kit.
Remove the toner cartridge and check for damage.
If necessary, replace it.
Remove the OPC drum cartridge and check for damage.
If necessary, replace the entire drum kit.