Page 1
A s s e m b l y I n s t r u c t i o n s GENIUS Elektronic door lock W I N D O W H A R D WA R E D O O R H A R D WA R E S L I D I N G D O O R H A R D WA R E D O O R H A R D WA R E V E N T I L AT I O N T E C H N O LO G Y...
Assembly instructions GENIUS Contents Target group of this documentation.............. 2 Intended use....................Improper use....................Safety notes....................2 Explanation of symbols................Rotary switch (optional signal outputs)............3 Installation....................GENIUS door lock connections..............5 Cable links....................Fitting the door contact................. 8 Fitting an internal release push-button (optional).......... 9 Fitting the infra-red eye (optional)..............
GENIUS Assembly instructions Target group of this documentation This documentation is intended to be used by specialists only. All work described in this document is to be performed by experienced professionals with training and practice in the assembly, installation and maintenance of the GENIUS door lock and its individual components.
Assembly instructions GENIUS Explanation of symbols Milling cutter or drill diame- Groove depth from profile Ø16 Groove length Rotary switch (optional signal outputs) • The rotary switch can only be operated when the lock is not installed. • The rotary switch is used to control the optional signal output, terminal 7. The output must not be subjected to a cur- rent of more than 20 mA.
GENIUS Assembly instructions Installation Fitting the GENIUS door lock The GENIUS door lock is supplied pre-installed. It only needs to be screwed in for retrofitting or replacement purposes. Fig. 2: Fitting the GENIUS door lock Fitting the power supply • The power supply ensures that the GENIUS door lock is supplied with the right voltage.
Assembly instructions GENIUS GENIUS door lock connections Connec- Type Type Function tions A, B, C, D Connection for infra-red eye, which sends infra-red signals to the GENIUS door lock Connection for the KFV fingerprint B, C, D, 2 scanner 0, 1 Switching between day/night mode 2, 3...
Page 8
GENIUS Assembly instructions Type K Cable Band Cable Function colour colour Switching between Black Grey day/night mode Switching between Brown Yellow day/night mode Yellow Green External "unlock" signal Violet Pink Indicating door/lock status -- /3 Blue Brown Operating voltage (--) negative Fig.
Assembly instructions GENIUS Cable links Visible cable link • The visible cable link should be fitted to the inside of the door on the hinge side. • If this cable link is used, unhinging the door leaf requires substantial effort. Fig.
GENIUS Assembly instructions Fitting the door contact Important: Do not allow the magnet to come directly into contact with the face plate as this can permanently magnetise the face plate or the drive rod behind it. • The GENIUS door lock uses an integrated door contact (reed sensor) to detect whether the door is open or shut. • The reed sensor is triggered by a counter part (magnet) that must be fitted on the frame side.
Assembly instructions GENIUS Fitting an internal release push-button (optional) The internal release push-button can be used to open the door without a conventional key. › Connect the cable (length: 750 mm) to terminals 2 and 4 on the GENIUS door lock. ›...
GENIUS Assembly instructions Wiring diagram for type A GENIUS door lock DSP 30 Kl. 4 Fl. ( +24 V DC) Description 230 V AC supply cable (L; N; PE) Power supply Wireless receiver (optional) External unlocking feature (optional) Max. line length 50 m (external unlocking feature) Max.
Assembly instructions GENIUS Wiring diagram for type B GENIUS door lock DSP 30 Kl. 4 Fl. ( +24 V DC) max. 20 mA Description 230 V AC supply line (L; N; PE) Power supply Wireless receiver (optional) External unlocking feature (optional) Max.
GENIUS Assembly instructions Technical specifications Relative humidity 20 % bis 80 % Ambient temperature in door -- 10 bis + 45 °C Dimensions Width 16 mm, length approx. 252 mm, depth 49 mm + width of face plate Supply voltage 24 V DC max.
Page 15
Assembly instructions GENIUS Last update: 01.08.2013...