Summary of Contents for Siegenia GENIUS 2.2 PANIC

  • Page 1 OPERATING INSTRUCTIONS DRIVE GENIUS 2.2 PANIC Electromechanical multi-point lock Window systems Door systems Comfort systems...
  • Page 3: Table Of Contents

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock Inhalt Check the locking and opening of the door ..........23 ABOUT THIS DOCUMENTATION ....4 Check the electromechanical locking and Target group ..........4 release ............23 Product description ........4 Check the activation force ......
  • Page 4: About This Documentation

    A company of the SIEGENIA GROUP trance doors. Siemensstraße 10 42551 Velbert • Use the GENIUS 2.2 PANIC as shown below: – in a technically sound condition Dimensions – only with original KFV products and accessories All dimensions are given in millimetres (mm).
  • Page 5: Transport

    Only use the shielded original KFV cable. The signal word "Warning" designates a potential hazard. If this hazard is not prevented, it could lead to • All functions of the GENIUS 2.2 PANIC are only com- death or severe injuries. pletely available after the described commissioning process.
  • Page 6: Variants And Components

    Auxiliary box Main lock Electromechanical drive Variants of auxiliary boxes GEP EP 9600 GEP EP 9500 GEP EP 9300 GENIUS 2.2 PANIC is available in 4 versions: GENIUS PANIC versions Functions 1-sash (CB) 2-sash (2F) Cylinder operated lock E ●...
  • Page 7: Functions

    • Locking in night mode: the door is automatically off. locked when it is closed. • The multi-point lock with GENIUS 2.2 PANIC will return to the • Locking in day mode: there is no automatic locking. locking position if the door is not opened during this period.
  • Page 8 DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock • Opening against the direction of escape: unlock the door using the key. Turn the key to the release stop. The lever handle against the direction of escape is coupled once. Opening the door using the lever handle.
  • Page 9: Connections And Operating Elements Genius 2.2 Panic

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock Connections and operating elements GENIUS 2.2 PANIC Item Function SI-BUS connection: terminal A/B: data interface SI-BUS terminal C: supply voltage (- ) GND terminal D: supply voltage + 24 V DC...
  • Page 10: Operation

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock Operation Menu navigation f To proceed to the menu, press the button on the GENIUS 2.2 PANIC for 8 seconds until the menu LED magenta lights up. The LED lights up blue or white during these 8 seconds.
  • Page 11: Menu Structure

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock f Hold down the button for 3 sec- onds to select a function. f An acoustic signal sounds as acknowledgement. f You will exit the menu. The menu settings are terminated without changes if there are no entries within a timeout of 30 seconds.
  • Page 12: Menu Functions

    Manual adjustment of day / night mode The GENIUS 2.2 PANIC enables use in two different modes of operation. In day mode the door is only used in latch function, the door is not completely locked when it is closed.
  • Page 13: Volume Of The Buzzer

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock 5.3.2 Volume of the buzzer The buzzer delivers the acoustic feedback of the opening process or malfunction. The volume for the feedback of the opening process is adjustable in five stages from 0 % to 100 %. Coupled to this is the sound volume of the button of the menu button with exception of the stage 0%.
  • Page 14: Feedback Function

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock 5.3.3 Feedback function The feedback function provides information on the status of the selected functions via an output contact (e. g. door closed and locked). This makes a potential-free switching output available for third party systems (e. g. alarm systems).
  • Page 15: Feedback Contact

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock 5.3.4 Feedback contact The feedback contact can also be set in its function as a locking bolt or as an opener. If the function "Locking bolt“ is selected, this will switch on the coupling relay when the status of the selected function is fulfilled (e.
  • Page 16: Day/Night Switchover

    E.g. the button with menu LED can be deactivated and, in return, an external switch ac- tivated in order to exclude an unauthorised switchover of the Day/Night mode on the GENIUS 2.2 PANIC. The last status set on the button remains.
  • Page 17: Cylinder Operated Lock

    Cylinder operated lock For special variants of GENIUS (e. g. GENIUS 2.2 PANIC with function B) or for locks without a main lock case, the function must be set to "Inactive" in the menu item "Latch in cylinder operated lock".
  • Page 18: Device Services

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock 5.3.7 Device services The menu "Device services" is for the purpose of commissioning or service. The following functions can be carried out in the menu „device services“: value Explanation Restarts the system...
  • Page 19: System Services

    All devices that are still connected remain coupled. The devices that are to be separated may no longer be physically connected to the SI-BUS. Premature unblocking of the SIEGENIA ACS, which has been blocked for a specific period due to erroneous informa- Unblock ACS tion.
  • Page 20: Wifi

    • password Coupling the devices via the the WPS mode in the home network. Following activation of this function, the SIEGENIA ACS searches 2 minutes for a WIFI access point with WPS mode. WPS mode The WIFI configuration is received and the WIFI connection is set up.
  • Page 21: Status Led And Troubleshooting

    You will find further information on the operation of the GENIUS 2.2 PANIC (e.g. in conjunction with the SIEGENIA access control system) as well as all FAQs on the topic of „SIEGENIA Smarthome“ on the following SIEGENIA Internet page: https://smarthome.siegenia.com...
  • Page 22: Monthly Testing And Maintenance

    Monthly testing and maintenance In accordance with DIN EN 179 and DIN EN 1125, testing and maintenance of the GENIUS 2.2 PANIC multi-point lock must be conducted after 20,000 opening cycles, and once a month at least. The results must be documented.
  • Page 23: Check The Locking And Opening Of The Door

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock Check the locking and opening of the door Switch the GENIUS 2.2 PANIC multi-point lock to day mode (see page 12). Test point Description Action Close the door The door must engage into the frame.
  • Page 24: Check The Activation Force

    GENIUS 2.2 PANIC, Electromechanical multi-point lock Check the activation force We recommend checking the activation force required for the release of the GENIUS 2.2 PANIC multi-point lock with a dynamometer. To obtain comparable values, the measurements must always be taken at the same location of the push bar/lever handle.
  • Page 25: Test And Maintenance Protocol

    Test and maintenance protocol Check for the original status Contact your contractual partner Additional locking systems added All components of the GENIUS 2.2 PANIC multi-point lock are compliant with the list of delivered/au- thorised components. Check screwing Contact your contractual partner Screwing of operating elements (lever handle or push bar) is tightened.
  • Page 26: Lubrication

    DRIVE - Operating instructions GENIUS 2.2 PANIC, Electromechanical multi-point lock 8.11 Lubrication All the lubrication points defined below must be lubricated if necessary, and at least once annually. WARNING Life-threatening danger in a panic situation Multi-functional oils or multi-purpose sprays will rinse off the original lubrication.