Siegenia AEROTUBE WRG smart Original Operating Instructions

Siegenia AEROTUBE WRG smart Original Operating Instructions

Hide thumbs Also See for AEROTUBE WRG smart:

Advertisement

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROTUBE WRG smart
AEROTUBE AZ smart
Wall-mounted ventilator with supply air and exhaust air function, temperature and
humidity regulation, optionally with heat recovery and CO
control
2
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEROTUBE WRG smart and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia AEROTUBE WRG smart

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROTUBE WRG smart AEROTUBE AZ smart Wall-mounted ventilator with supply air and exhaust air function, temperature and humidity regulation, optionally with heat recovery and CO control Window systems Door systems Comfort systems...
  • Page 3: Table Of Contents

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Contents TARGET GROUP OF THIS OPERATION..........24 DOCUMENTATION ........4 10.1. Operation.via.button.on.the.device .... 24 INTENDED USE ..........4 10.2. Operation.via.smartphone.or.tablet ... 25 SAFETY NOTES ...........5 MAINTENANCE ........27 GENERAL NOTES ........5 11.1 Notes on cleaning and maintenance ... 27 11.2...
  • Page 4: Target Group Of This Documentation

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Target group of this documentation • This.documentation.is.intended.for.use.by.specialists. decentralised.ventilation.units. and end users. • All.notes.on.operation.and.maintenance.as.well.as. • All.instructions.concerning.assembly,.installation. the.rectification.of.malfunctions.described.here.are. and.repairs.described.in.this.document.are.to.be. intended for specialists and end users. performed.exclusively.by.experienced.professionals. • After.the.successful.assembly.and.installation,.the. with.training.and.practice.in.the.installation,. installation.company.is.committed.to.handing.over. commissioning, servicing and maintenance of the.original.operating.instructions.to.the.end.user.
  • Page 5: Safety Notes

    – If the SIEGENIA WIFI devices are integrated in – If.any.work.is.required.for.the.connection.of.the. your.home.WIFI,.this.must.be.encrypted.for. device to the 230 V AC mains power supply, this operation. may.only.be.carried.out.by.an.electrician. – Please.choose.secure.passwords.consisting.of.
  • Page 6: Scope Of Delivery And Accessories

    Stainless steel weather grille hood Axial.ventilator Wall.fixing Pipe inset (2-part) Fixing set Filter holder WRG (AEROTUBE WRG smart) Filter ISO coarse 45 % (AEROTUBE WRG smart) Ceramic heat accumulator (AEROTUBE WRG smart) Ventilation.pipe.Ø.160 Bag of screws (4 screws and dowels) Original.operating.instructions...
  • Page 7: Vent Duct Epp

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 6.3 Vent duct EPP Item name Plastic.cover Vent.duct.EPP,.type.FL Corner.drive.SFL Transition.piece.SFL Accessories Item name Material number Weather grille perforated vL5474620-500010 brick.aluminium Weather grille perforated vL5474610-500010 grille aluminium Weather grille lamella...
  • Page 8: Assembly

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Assembly 7.1 Installation requirements 7.2 Installation of ventilation pipe and PVC weather grille D 160 • The.installation.site.of.AEROTUBE.should.not.be. accessible.to.third.parties. 7.2.1 Drilling the core hole (room side) and • Suitable.clamps.must.be.selected.according.to.the. installation of ventilation pipe composition.of.the.installation.site.and.provided.by.
  • Page 9 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Drill the core hole Slide.mounting.cover.for.weather.grille.onto.the.pipe In order for condensate to drain outwards, the hole.must.have.an.incline.of.0.5–2°..However,.the. slope.must.not.exceed.3°.as.this.would.make.it. impossible.to.remove.the.pipe.inset.from.the. ventilation.pipe.for.maintenance.purposes. Remove.mounting.cover.and.complete.pipe.inset Insert.pipe.with.mounting.cover.into.the.wall Shorten pipe (minimum length for pipe = 270 mm) Insulate.pipe.up.to.the.mounting.cover.(according.to.
  • Page 10 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.2.2 Installation of PVC weather grille D 1600 Plaster the outside wall Seal weather grille Remove.mounting.cover.and.seal.pipe Position.weather.grille.and.press.firmly.against.the.wall inside.=.airtight.seal The lamellae of the weather grille must point outside = free-air seal downwards.
  • Page 11: Installation Of Ventilation Pipe And Stainless Steel Weather Grille Cover Or Stainless Steel / Aluminium-Zinc Weather Grille

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.3 Installation of ventilation pipe and stainless steel weather grille cover or stainless steel / aluminium-zinc weather grille 7.3.1 Drilling the core hole (room side) and installation of ventilation pipe...
  • Page 12 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.3.2 Mounting the stainless steel / aluminium-zinc weather grille Position.weather.grille.and.glue.into.place insert pipe in the wall The lamellae of the weather grille must point downwards. insulate.pipe.(according.to.requirement) seal pipe inside.=.airtight.seal outside = free-air seal 12/40 02.2022...
  • Page 13 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.3.3 Installation of stainless steel weather grille cover Adjust.wall.fixing.①.and.mark.fixing.holes.② Adjust.weather.grille.cover.to.the.cable.outlets.of.the. wall.fixing Drill.fixing.holes.and.insert.dowels Hook.weather.grille.cover.into.the.wall.fixing Fix.wall.fixing.with.screws Fix weather grille cover with screw H47.WANS008EN-07 02.2022 13/40...
  • Page 14: Installation.of.ventilation.pipe.and Vent Duct Epp

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.4 Installation of ventilation pipe and vent duct EPP 7.4.1 Drilling the core hole (room side) and installation of ventilation pipe NOTICE Material damage due to holes in the wall You.can.damage.cables.or.lines.while.drilling.into.the.wall.
  • Page 15 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart insert pipe in the wall Ventilation.pipe insulate.pipe.(according.to.requirement) Shorten.pipe: A insertion.depth.of.ventilation.pipe.in.vent.duct. seal pipe EPP.(min..8.mm;.max..15.mm) + B back-up.insulation.of.vent.duct.(combine. inside.=.airtight.seal insulation.plates.according.to.required.wall. outside = free-air seal insulation) + C wall thickness incl. plaster pipe length (min.
  • Page 16 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.4.2 Installation of vent duct type FL Shorten.duct.using.a.saw.or.cutter.knife.within.the. Insert.plastic.cover marked.area.if.required. Position.duct.on.pipe.and.fix.to.outside.wall.(screw.or. There.is.a.separating.bar.inside.the.duct..If.the. glue) duct.is.shortened.by.more.than.200.mm,.the. separating.bar.must.be.cut.using.the.cutter.knife. 16/40 02.2022 H47.WANS008EN-07...
  • Page 17 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Attach.thermal.insulation Remove.plastic.cover Attach.thermal.insulation Position.outlet.duct.and.weather.grille.in.the.vent.duct Plaster the wall and duct Fix the weather grille with dowels/screws H47.WANS008EN-07 02.2022 17/40...
  • Page 18 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.4.3 Installation of vent duct type SFL There.is.a.separating.bar.inside.the.duct..If.the. duct.is.shortened.by.more.than.200.mm,.the. separating.bar.must.be.cut.using.the.cutter.knife. ② ① Slide.transition.piece.onto.corner.drive..The.corner. Insert.plastic.cover.①,.②.fix.transition.piece.to. drive.can.point.to.the.left.or.right.according.to.the. corner drive with adhesive tape installation.location. Shorten.duct.using.a.saw.or.cutter.knife.within.the. Position.duct.on.pipe.and.fix.to.outside.wall.(screw.or. marked.area.if.required. glue) 18/40 02.2022 H47.WANS008EN-07...
  • Page 19 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Attach.thermal.insulation Remove.plastic.cover Attach.thermal.insulation Position.outlet.duct.①.and.weather.grille.②.in.the. vent duct Plaster the wall and duct Fix the weather grille with dowels/screws H47.WANS008EN-07 02.2022 19/40...
  • Page 20: Installation.of.the.inner.panel.e28

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 7.5 Installation of the inner panel E28 Drill.fixing.holes.and.route.cable Remove inner panel Push.complete.pipe.inset.with.mounting.cover.into.the. Remove electronics cover pipe Plaster the wall Remove.mounting.cover 20/40 02.2022 H47.WANS008EN-07...
  • Page 21 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Position.the.casing Clip electronic cover into place Fix the casing Connect.axial.ventilator 1 2 3 N L1 1 2 3 N L1 Connect.cable:.①.=.standard;.②.=.bathroom.control Clip on inner panel The.cable.outlet.in.the.inner.panel.must.be.on.the. slider side. H47.WANS008EN-07 02.2022...
  • Page 22: Unit Function

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Unit function 8.1 Ventilation and air extraction with 8.1.4 Ventilation in automatic mode blowers • The.blower.levels.1.to.3.are.controlled.in.automatic. 8.1.1 Supply air operation mode..The.necessary.blower.level.is.dependent. on the temperature and air humidity as well as •...
  • Page 23: Button.and.led.indicator

    • The. e lectrical. s lider. o pens. a utomatically. w hen. t he. A EROTUBE only be changed or deactivated via the SIEGENIA Comfort app. is. s witched. o n. a nd. c loses. a utomatically. w hen. t he. A EROTUBE is.switched.off.
  • Page 24: Commissioning

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Commissioning 9.1 Notes on calibration 9.2 Performance of calibration • For.units.with.air.quality.sensors,.a.one-off. 1. Air the room thoroughly for 10 min. calibration.of.the.sensor.is.performed.during. the commissioning. The sensor adapts to the 2. Switch AEROTUBE to the electricity grid.
  • Page 25: Operation.via.smartphone.or.tablet

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 10.2 Operation via smartphone or tablet 10.2.1 Functional mode 10.2.3 Control of the device functions The AEROTUBE.smart.can.be.controlled.by.smartphone. Blower performance or.tablet.and.offers.additional.device.functions.via.the. SIEGENIA Comfort app. The.blower.performance.can.be.set.manually. On.application.of.bathroom.control,.automatic.mode,. silent.mode.or.timer,.the.manually.adjusted.blower. performance is overridden.
  • Page 26 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Bathroom control Silent mode If a AEROTUBE.is.connected.to.an.external.bathroom. The.silent.mode.restricts.the.blower.performance,.thus. light.switch,.the."bathroom.control".function.enables. overriding.all.blower.levels.that.are.programmed.in. follow-up.operation.for.an.individually.adjustable.time. other.functions.(e..g..timer.or.bathroom.control)..The. after.the.light.has.been.switched.off. silent.mode.can.therefore.guarantee.silent.ventilation. For.information.concerning.the.connection.of.a. Timer bathroom.light.switch.to.a.AEROTUBE, see page 21. The.timer.function.enables.the.adjustment.of.up.to.5. Bathroom.active:.the.AEROTUBE, which is connected different.time.programs..The.starting.and.running.time. to.the.external.bathroom.switch. as.well.as.weekdays,.mode.of.operation.and.blower. performance.can.be.freely.defined.according.to.the.
  • Page 27: Maintenance

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 11 Maintenance 11.2 Filter replacement and cleaning DANGER of ceramic heat accumulator Exposed electrical components when the inner panel is (AEROTUBE WRG smart) removed Risk.of.fatal.injury.from.electric.shock.or.fire WARNING • for.all.devices.with.a.fixed.connection.to.the.230.V.AC. High weight of the ceramic heat accumulator in the pipe mains.power.supply,.switch.off.all.poles.of.the.feeder..
  • Page 28 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Dispose.of.the.old.filter Clean ceramic heat accumulator and leave to dry Do.not.bend.the.retaining.clips.to.the.side.-.this. leads to damage! 1. Carefully release the retaining clips of the pipe inset. 2. Carefully draw the top pipe inset upwards.
  • Page 29 Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart Clip on top pipe inset Clip on inner panel The.cable.outlet.in.the.inner.panel.must.be.on.the. slider side. Push complete pipe inset into pipe Reset.filter.replacement.indicator.via.SIEGENIA. Comfort app Connect.axial.ventilator H47.WANS008EN-07 02.2022 29/40...
  • Page 30: Filter Replacement (Aerotube Az Smart)

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 11.3 Filter replacement (AEROTUBE AZ smart) Insert.the.new.filter.and.filter.holder Remove inner panel Remove.filter.holder.and.filter Clip on inner panel The.cable.outlet.in.the.inner.panel.must.be.on.the. slider side. Dispose.of.the.old.filter Reset.filter.replacement.indicator.via.SIEGENIA. Comfort app 30/40 02.2022 H47.WANS008EN-07...
  • Page 31: Rectification Of Malfunctions

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 12 Rectification of malfunctions In.case.of.a.malfunction,.do.not.open.the.unit.or.try.to. If.the.problem.is.not.described.in.the.table.below,. repair it under any circumstances. please.contact.your.installation.firm.or.SIEGENIA. directly,.tel..+49.271.3931-0 Problem Possible cause Solution No power supply Check power supply AEROTUBE shows no Wiring.wrong/defective.or.cable. Have.the.wiring.checked.by.a.qualified. reaction.when.button.is.
  • Page 32: Technical Specifications

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 13 Technical specifications 13.1 Data table AEROTUBE WRG smart AEROTUBE AZ smart Air throughput at.blower.level.1 approx. 15 m³/h approx. 24 m³/h at.blower.level.2 approx. 32 m³/h approx. 43 m³/h at.blower.level.3 approx.
  • Page 33: Product.fiche

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 13.2 Product fiche according to EU Regulation 1254/2014 1253/2014 Producer SIEGENIA SIEGENIA b Model.identifier AEROTUBE WRG smart AEROTUBE AZ smart Energy.consumption.(SEV); −17.62 kWh/(m².·.a);.E −10.99 kWh/(m².·.a);.E Energy.efficiency.class.(SEC.class) ―42.15 kWh/(m².·.a);.A+ ―25.36 kWh/(m².·.a);.C (according.to.climatic.zone.warm./.average./. ―84.96 kWh/(m².·.a);.A+ ―50.44 kWh/(m².·.a);.A+...
  • Page 34: Dimensions Aerotube And Weather Grill Variants

    Stainless steel weather grille hood Stainless steel / aluminium-zinc weather grille Weather grille PVC D 160 (AEROTUBE DD 160) Ventilation.pipe.Ø.160 Ceramic heat accumulator (AEROTUBE WRG smart) Filter ISO coarse 45 % (AEROTUBE WRG smart) Axial.ventilator Pipe inset (2-part) Inner panel E28 34/40 02.2022...
  • Page 35: Dimensions Of Vent Duct Epp

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 13.4 Dimensions of vent duct EPP Vent duct EPP, type FL Vent duct EPP, type SFL: penetration.area cropping area e.g..for.screws.or.insulation.material.dowels H47.WANS008EN-07 02.2022 35/40...
  • Page 36: Dimensions Of Accessories For Vent Duct Epp

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 13.5 Dimensions of accessories for vent duct EPP Weather grille perforated grille Weather grille perforated brick Weather grille, lamella aluminium aluminium extension for vent duct EPP, type SFL penetration.area cropping area e.g..for.screws.or.insulation.material.dowels...
  • Page 37: Eu Declaration Of Conformity With Regard To Ce Marking

    Original operating instructions AERO AEROTUBE WRG smart / AEROTUBE AZ smart 14 EU Declaration of Conformity with regard to CE marking For our product AEROTUBE,.we.confirm.that.the.general.safety.of.the.defined.product,.in.accordance.with.Di- rective.2001/95/EC,.is.compliant.with.the.relevant.protection.requirements.which.are.laid.down.in.the.Council. Directives.about.electrical.and.electronic.products. The.following.listed.test.standards,.which.are.harmonised.in.the.relevant.directives,.have.been.employed.for.the. evaluation: 2014/30/EC EMC Directive EN.55014-1:2006+A1:2009+A2:2011 EN.55014-2:1997+A1:2001+A2:2008 EN.61000-3-2:2014 EN.61000-3-3:2013 2014/35/EC Low voltage directive EN.60335-1:2012+A11:2014...
  • Page 40 www.siegenia.com...

This manual is also suitable for:

Aerotube az smart

Table of Contents