2.2. GEYSIR AIR

Dimensions and connections
The brine lines can be connected on either the left or right-hand
sides of the heat pump.
40±10
455
596
80
5
7 8
56
4
74
Figure 4: Geysir Air, Dimensions and connections.
Q
Brine return line (Brine in), 28 Cu
W
Brine supply line (Brine out), 28 Cu
E
Lead-in for incoming power supply, sensors and
communication cable
R
Heating system supply line, 22 Cu: 6-10 kW, 28
Cu: 12 kW
T
Heating system return line, 22 Cu: 6-10 kW, 28
Cu: 12 kW
Y
Expansion pipe, 22 Cu
U
Hot water pipe, 22 Cu or stainless steel
I
Cold water line, 22 Cu or stainless steel
O
Lifting point
P
Expansion outlet brine circuit, R25 int.
300
2
250
1
10
9
6
3
327
1
2
Figure 5: Outdoor unit, Dimensions and connections.
Q
Brine in (HP Brine out) 28 Cu
W
Brine out (HP Brine in) 28 Cu
2
3
1
5
4
Figure 6: Outdoor unit components and connections
Q
Outdoor unit
W
Cover
E
Front cover
R
Stand
T
Cover
Y
Connection, brine in
U
Connection, brine out
I
Connection, drain drip tray
Check that the delivery of the outdoor unit contains the
following:
• Outdoor unit
• Disassembled stand
• Necessary screws, nuts and washers.
• Defroster sensor
2
1
1175
6
7
8
7
ENGLISH