York TH4 Series Installation Manual

R-410a outdoor split-system heat pump
Hide thumbs Also See for TH4 Series:

Advertisement

Quick Links

INSTALLATION MANUAL
R-410A OUTDOOR SPLIT-SYSTEM
HEAT PUMP
MODELS: 14 SEER -
YHE, TH4, THE, RHP14L SERIES
1.5 TO 5 TONS - 1 & 3 PHASE
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INDOOR EXPANSION DEVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
SYSTEM CHARGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Typical Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Alternative Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Installation of Vapor Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Underground Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Heat Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TXV Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
TXV Bulb and Equalizer Line Installations . . . . . . . . . . . . . . . . . . . . . .6
Proper Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Outdoor Unit Swing Away Control Box . . . . . . . . . . . . . . . . . . . . . . .11
(Single and Three-Phase) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Maximum / Minimum Operating Limit Conditions . . . . . . . . . . . . . . . . .2
R-410A Saturation Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
YHE18 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
YHE24 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
YHE30 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
YHE35 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
YHE36 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
SECTION I: GENERAL
The outdoor units are designed to be connected to a matching indoor
coil with sweat connect lines. Sweat connect units are factory charged
with refrigerant for a nominal sized matching indoor coil plus 15 feet of
field-supplied lines.
Matching indoor coils can be used with a thermostatic expansion valve
(TXV). Refer to the Tabular Data Sheet or to the Technical Guide for
the proper selection.
Johnson Controls Ducted Systems
LIST OF SECTIONS
ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SYSTEM START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SYSTEM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
INSTRUCTING THE OWNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
START UP SHEET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
LIST OF FIGURES
Heat Pump Flow Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Demand Defrost Control Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Defrost Operation Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
(18,24,30,35,48,60) Gen1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
for models (36,42) Gen2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
for models (30,48,60)31S Gen1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
for models (30,48,60)41S Gen1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
for models (36,42)B(32,42)s Gen2 . . . . . . . . . . . . . . . . . . . . . . . . . . 21
LIST OF TABLES
YHE42 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
YHE48 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
YHE60 Heat Charging Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TEST Input Functionality with Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
TEST Input Functionality without Y . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Status Code Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SECTION II: SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
® ® ® ®
5604542-UIM-B-0419

Advertisement

Table of Contents
loading

Summary of Contents for York TH4 Series

  • Page 1: Table Of Contents

    INSTALLATION MANUAL R-410A OUTDOOR SPLIT-SYSTEM ® ® ® ® HEAT PUMP MODELS: 14 SEER - YHE, TH4, THE, RHP14L SERIES 1.5 TO 5 TONS – 1 & 3 PHASE LIST OF SECTIONS GENERAL ..........1 ELECTRICAL CONNECTIONS .
  • Page 2: Unit Installation

    5604542-UIM-B-0419 WARNING 5. The maximum allowable line length for this product is 80 feet. To install more than the maximum allowable line length, consult the Piping Application Guide (P/N 247077). Improper installation may create a condition where the operation of SECTION III: UNIT INSTALLATION the product could cause personal injury or property damage.
  • Page 3: Typical Installation Clearances

    5604542-UIM-B-0419 FIGURE 1: Typical Installation Clearances FIGURE 2: Alternative Installation Clearances Johnson Controls Ducted Systems...
  • Page 4: Installation Of Vapor Line

    5604542-UIM-B-0419 GROUND INSTALLATION R-410A Filter-Drier Source 1 Part No. Apply with Models The unit may be installed at ground level on a solid base that will not S1-32649682000 shift or settle, causing strain on the refrigerant lines and possible leaks. PIPING CONNECTIONS The unit must be installed in as level a position as possible while main- taining the clearances shown in Figures 1 &...
  • Page 5: Underground Installation

    5604542-UIM-B-0419 7. Pack fiberglass insulation and a sealing material such as perma- 3. Carefully remove the plugs from the liquid and vapor connections at gum around refrigerant lines where they penetrate a wall to reduce the indoor coil. vibration and to retain some flexibility. 8.
  • Page 6: Indoor Expansion Device

    5604542-UIM-B-0419 12. Release the refrigerant charge into the system. Open the liquid line valve first, then the vapor line valve by removing the plunger cap and turning the valve counter-clockwise using hex head wrenches. LIQUID LINE / TXV COUPLING Valves are fully open when the valve stem is touching the cham- fered retaining wall at the top of the valve.
  • Page 7: Evacuation

    5604542-UIM-B-0419 8. Install the TXV bulb to the vapor line near the cabinet, using the To measure actual air flow, it is not an acceptable method to just bulb clamp(s) furnished with the TXV assembly. Ensure the bulb is check the jumper pin setting tables and is to assume 0.5” water making maximum contact.
  • Page 8: R-410A Saturation Properties

    5604542-UIM-B-0419 CHARGING WITH GAUGES Before using gauges, confirm that your gauges are accurate by comparing the gauges against a calibrated pressure gauge that CAUTION has been calibrated against a national standard. If a calibrated pressure gauge is not available, place a R-410A virgin refrigerant Refrigerant charging should only be carried out by a qualified air con- container in a conditioned space long enough to come to tempera- ditioning contractor.
  • Page 9: Yhe30 Heat Charging Charts

    5604542-UIM-B-0419 TABLE 5: YHE30 Heat Charging Charts YHE/TH4/THE/RHP14L30 AE30, RFCX30BE Ambient Temperature (°F) Indoor Temperature (°F) Liquid Pressure (PSIG) 379 428 477 355 420 302 343 384 295 336 378 1000 Liquid Pressure (PSIG) 349 397 445 329 396 285 324 364 278 318 358 1200 Liquid Pressure (PSIG) 320 366 413 303...
  • Page 10: Yhe42 Heat Charging Charts

    5604542-UIM-B-0419 TABLE 8: YHE42 Heat Charging Charts YHE/TH4/THE/RHP14L42 CF/CM/CU48, AP48, AE(42,48), AVC(42,48), RFCX42CE, RFCX48(C,D)(P,E) Ambient Temperature (°F) Indoor Temperature (°F) 1150 Liquid Pressure (PSIG) 453 505 362 407 453 332 376 421 306 337 330 242 278 1400 Liquid Pressure (PSIG) 426 477 343 387 432 316 358 402 293 326 321 234 269 1650...
  • Page 11: Outdoor Unit Swing Away Control Box

    5604542-UIM-B-0419 SECTION VII: ELECTRICAL FIELD CONNECTIONS POWER WIRING CONNECTIONS 1. Install the proper size weatherproof disconnect switch outdoors and within sight of the unit. GENERAL INFORMATION & GROUNDING 2. Remove the screws at the top and sides of the corner cover. Slide The control box cover is held in place with 3 screws (one screw in each the control box cover down and remove from unit.
  • Page 12: Typical Field Wiring (Air Handler / Electrical Heat)

    5604542-UIM-B-0419 FIELD CONNECTIONS CONTROL WIRING DEHUMIDIFICATION CONTROL (Typical) 1. Route low voltage wiring into bottom of control box as shown in Fig- The indoor unit Installation Manual instructions for the air handler or fur- ure 10 or 11. Make low voltage wiring connections inside the low nace describe the interface with the outdoor heat pump.
  • Page 13: System Operation

    5604542-UIM-B-0419 SECTION IX: SYSTEM OPERATION LOW VOLTAGE DETECTION ANTI SHORT-CYCLE DELAY The control monitors the transformer secondary (24 VAC) voltage and provides low voltage protection for the heat pump and its components. The control includes a five-minute anti short-cycle delay (ASCD) timer In particular, the control prevents contactor chatter during low voltage to prevent the compressor from short-cycling after a power or thermo- conditions.
  • Page 14: Demand Defrost Control Module

    5604542-UIM-B-0419 FIGURE 14: Demand Defrost Control Module FAULT CODE DISPLAY TABLE 14: Status The control shall provide status codes using the LED. Status codes Description STATUS LED indicate the state of operation of the unit but do not represent a fault. The table below describes the LED displays during status codes.
  • Page 15: Defrost Operation Curves

    5604542-UIM-B-0419 Operation The control shall initiate a defrost cycle when the Defrost Inhibit Time Limit has elapsed if the previous defrost cycle was terminated based on The defrost mode is equivalent to the cooling mode except that the out- the Maximum Defrost Cycle Time. This shall occur regardless of the liq- door fan motor is de-energized.
  • Page 16: Instructing The Owner

    5604542-UIM-B-0419 COOLING OPERATION When the soft lockout condition is reset, the control will stop displaying the fault code and will respond to thermostat inputs normally. During cooling operation, the control will receive thermostat signals at SECTION X: INSTRUCTING THE OWNER the Y and O input terminals.
  • Page 17: Wiring Diagram

    5604542-UIM-B-0419 SECTION XI: WIRING DIAGRAM LEGEND COLOR CODE DANGER - SHOCK HAZARD TURN OFF ELECTRICAL POWER BEFORE SERVICING AS - AMBIENT SENSOR BLK - BLACK TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT CAP - CAPACITOR BLK/PNK - BLACK w/PINK STRIPE AND POSSIBLE PERSONAL INJURY.
  • Page 18: Wiring Diagram - Single Phase Ecm 208/230 For Models (36,42) Gen2

    5604542-UIM-B-0419 DANGER - SHOCK HAZARD COLOR CODE LEGEND TURN OFF ELECTRICAL POWER BEFORE BLK - BLACK AS - AMBIENT SENSOR SERVICING TO PREVENT POSSIBLE DAMAGE BLK/PNK - BLACK w/PINK STRIPE CAP - CAPACITOR TO THE EQUIPMENT AND POSSIBLE PERSONAL BLU - BLUE INJURY.
  • Page 19: Wiring Diagram - Three Phase Psc 208/230V Motor For Models (30,48,60)31S Gen1

    5604542-UIM-B-0419 LEGEND COLOR CODE DANGER - SHOCK HAZARD TURN OFF ELECTRICAL POWER BEFORE SERVICING AS - AMBIENT SENSOR BLK - BLACK TO PREVENT POSSIBLE DAMAGE TO THE CAP - CAPACITOR BLU - BLUE EQUIPMENT AND POSSIBLE PERSONAL INJURY. CC - CONTACTOR COIL BRN - BROWN CCH - CRANKCASE HEATER GRN - GREEN...
  • Page 20: Wiring Diagram - Three Phase Psc 460V Motor For Models (30,48,60)41S Gen1

    5604542-UIM-B-0419 LEGEND COLOR CODE DANGER - SHOCK HAZARD TURN OFF ELECTRICAL POWER BEFORE SERVICING AS - AMBIENT SENSOR BLK - BLACK TO PREVENT POSSIBLE DAMAGE TO THE CAP - CAPACITOR BLK/WHT - BLACK w/ EQUIPMENT AND POSSIBLE PERSONAL INJURY. CC - CONTACTOR COIL WHITE STRIPE CCH - CRANKCASE HEATER BLU - BLUE...
  • Page 21: Wiring Diagram - Three Phase Ecm 208/230&460V Motor For Models (36,42)B(32,42)S Gen2

    5604542-UIM-B-0419 COLOR CODE LEGEND DANGER - SHOCK HAZARD BLK - BLACK TURN OFF ELECTRICAL POWER BEFORE AS - AMBIENT SENSOR BLK/PNK - BLACK w/PINK STRIPE SERVICING TO PREVENT POSSIBLE DAMAGE CAP - CAPACITOR BLU - BLUE TO THE EQUIPMENT AND POSSIBLE PERSONAL CC - CONTACTOR COIL INJURY.
  • Page 22 5604542-UIM-B-0419 NOTES Johnson Controls Ducted Systems...
  • Page 23: Start Up Sheet

    5604542-UIM-B-0419 SECTION XII: START UP SHEET Heat Pump and Supplementary Heat Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity Start-Up Date Technician Performing Start-Up Installing Contractor Name Owner Information Name Address City State or Province Zip or Postal Code Equipment Data Upflow Downflow...
  • Page 24 Explain the importance of regular filter replacement and equipment maintenance Comments Section Page 2 of 2 Subject to change without notice. Published in U.S.A. 5604542-UIM-B-0419 Copyright © 2019 by Johnson Controls. All rights reserved. Supersedes: 5604542-UIM-A-0319 York International Corp. 5005 York Drive Norman, OK 73069...

Table of Contents