Owner's Manual
Congratulations. By purchasing this system, you have taken the first step
in ensuring safe drinking water. Designed using the most advanced UV
technology available today, your UV system is designed to provide you
with years of trouble-free operation with minimal maintenance required.
Date of installation:
Installed by:
Installer phone#:
Serial #:
(Found on label on back of TrojanUVMax A DWS)
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • tf. 1.800.265.7246 (US and Canada only)
f. (+1) 519.763.5069 • t. +31 73 623 8116 (Europe only)
e-mail: info@viqua.com
www.viqua.com
520173-R-RevD

Advertisement

loading
Need help?

Need help?

Do you have a question about the UVMax DWS11-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Viqua UVMax DWS11-A

  • Page 1 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 f. (+1) 519.763.5069 • t. +31 73 623 8116 (Europe only) t. (+1) 519.763.1032 • tf. 1.800.265.7246 (US and Canada only) 520173-R-RevD e-mail: info@viqua.com www.viqua.com f. (+1) 519.763.5069 • t. +31 73 623 8116 (Europe only) e-mail: info@viqua.com...
  • Page 2 Potential Safety Measures Hazard UV Exposure Never illuminate UV Lamp outside of the UV Chamber. Never look directly at illuminated UV Lamp, even when using protective gear. Always use protective gear, including gloves and UV safety glasses. If accidental exposure occurs, immediately cool affected area and consult physician.
  • Page 3 TABLE OF CONTENTS Components ........1 Safety Instructions .
  • Page 4 COMPONENTS SPECIFICATIONS For replacement components please contact your installer or contact VIQUA directly for a referral: 1 800 265 7246 (North America), 519 763 1032, or info@viqua.com. Specifications Operating Parameters Maximum operating pressure 125 PSI (862 kPa) Minimum operating pressure 4 PSI (27.5 kPa)
  • Page 5 VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA’s liability shall, in all instances, never use an adapter.
  • Page 6 VIQUA warrants original lamps and sleeves to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
  • Page 7 WATER CHEMISTRY Screw lamp into sleeve hand-tight. 11. Reinstall sleeve bolt with 2 new Caution: Over tightening will break o-rings. the sleeve. Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation: •...
  • Page 8 For shipping purposes, SLEEVE CLEANING AND LAMP REPLACEMENT Insert Lamp/ the UV lamp and sleeve sleeve assembly are shipped in a separate and screw into Turn off the shut-off valve situated by the inlet of the drinking water system. cardboard box. Carefully chamber.