Viqua VH150 Owner's Manual
Viqua VH150 Owner's Manual

Viqua VH150 Owner's Manual

Ultraviolet (uv) water disinfection system

Advertisement

425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1
t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only)
t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069
e-mail: info@viqua.com
www.viqua.com
Owner's Manual
Powered by
Models:
VH150, VH200, VH410, VP600, VP950,
VH410M, VP600M, VP950M
NSF Standard 55 Class B
Validated Models:
VH200-V, VH410-V, VH410M-V
System Tested and Certified by
NSF International against CSA
B483.1 and NSF/ANSI 55 for
Disinfection Performance, Class B
520110_RevY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VH150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viqua VH150

  • Page 1 Owner’s Manual Models: VH150, VH200, VH410, VP600, VP950, VH410M, VP600M, VP950M NSF Standard 55 Class B Validated Models: VH200-V, VH410-V, VH410M-V Powered by System Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class B 425 Clair Rd.
  • Page 2 • VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.
  • Page 3: Safety Information

    Safety Information Section 1 Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
  • Page 4 Safety Information WA R N I N G • During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
  • Page 5: General Information

    Controller (for 100-240V/50-60Hz models BA-ICE-C VP600, VP950 only) BA-ICE-CM VH410M, VH410M-V, VP600M, VP950M VH150, VH200, VH410, VH410M, VH200-V, VH410-V, VH410M-V, VP600, 602636 VP600M, VP950, VP950M (N. America) VH150/2, VH200/2, VH410/2, VH410M/2, VH200-V/2, VH410-V/2, VH410M-V/ 602637 2, VP600/2, VP600M/2, VP950/2, VP950M/2 (EU CEE)
  • Page 6: Installation

    Installation UV Sensor 254NM-C1 VH410M, VH410M-V, VP600M, VP950M Spring SP008 Used on all systems Retaining nut with the plug RN-001/1 Used on all systems Section 3 Installation 3.1 UV Disinfection System C A U T I O N Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle and the lamp connector ground wire connected to the stainless steel chamber.
  • Page 7 Installation Procedure: Figure 3 shows the installation of a typical disinfection system and the related components that may be used for the installation. The use of a by-pass assembly is recommended in case the system requires “off-line” maintenance. In this case, note the system requires a supplementary disinfection for the distribution system if any water is used during by- pass condition.
  • Page 8 Figure 5 Flow Restrictor 4. Mount the VIQUA ICE controller horizontally to the wall, near the chamber. Ideally place the controller above the chamber and away from any water connection point, to prevent any water from potentially leaking onto the controller by means of a leak at a connection point or a “sweating”...
  • Page 9: Disinfection Procedure

    Installation 6. When all plumbing connections are complete, slowly turn on the water supply and check for leaks. The most likely cause of leaks is from the O-ring seal. In case of a leak, shut water off, drain cell, remove the retaining nut, wipe the O-ring and threads.
  • Page 10: Maintenance

    Maintenance Notes: 1) The addition of chlorine (bleach) to a hot water tank that has in the past been fed with untreated raw water with high levels of other contaminants (iron, manganese, hydrogen sulphide, organics, etc.) will result in oxidation of these contaminants and may require repeated flushing of the hot water tank. This contingency must be dealt with independently under the start-up procedure for any other conditioners that may form a part of the pre-treatment for the UV unit.
  • Page 11 Maintenance click • Hold down the timer reset • Insert the new lamp fully into • Attach the connector to the • Push the lamp connector button and reapply power to the chamber leaving about lamp and note that the against lamp connector base the controller until you see two inches of the lamp...
  • Page 12 Maintenance Procedure: • Drain the chamber by using • Remove the top retaining nut • Remove the quartz sleeve. • Remove the bottom retaining the drain port. nut, floating spring, and O- and O-ring. ring. click Mild Acid • Clean the quartz sleeve with a •...
  • Page 13: Operation

    Operation Procedure:. 30 mins Commercial Scale Remover • Disconnect the UV sensor from • Remove the UV sensor by grasping • Clean the sensor with a cotton • Submerge only the end of the the body of the sensor and rotating the controller by disconnecting the sensor in the commercial scale swab and spray with water.
  • Page 14 The VIQUA Plus series of products incorporate a UV sensor which detects the discrete 254 nm wavelength of the UV lamp. This information is relayed to the VIQUA controller and is the default display shown in “% UV output”. The system will display the UV output between 50 to 99 percent.
  • Page 15 Section 5.1.5 for explanation of this feature. Note: On the VIQUA systems, the audible tone provided for lamp failure is a continuous alarm, rather than the intermittent (1 second on, 1 second off) condition on the basic VIQUA systems. 5.2.5 Solenoid Output Working in conjunction with the UV intensity monitor, the VIQUA controller provides a powered (line voltage) IEC solenoid output connector.
  • Page 16 Operation temporarily enable the operation of this solenoid output for up to 12 hours, please refer to the instructions outlined in Section 5.2.1). Optional Solenoid Valve Figure 7 Solenoid Installation Note: During bypass, do not consume the water until the system has returned to a safe condition. 5.2.6 4-20mA Output (Optional) To achieve the capability to transmit the UV intensity data to a remote location via a 4-20 mA signal, use an optional “Y”...
  • Page 17: Section 6 Troubleshooting

    Troubleshooting Section 6 Troubleshooting Symptom Possible Causes Solutions Replace filter cartridge with appropriate 5 micron cartridge. Sediment pre-filter clogged Note: Check source water supply as fluctuations may occur in source pressure. Pressure Drop Flow regulator Flow regulator will result in pressure drop when approaching full flow. Clean sleeve with scale cleaner and eliminate source of staining problem (ie.
  • Page 18: Specifications

    @ 95% UVT m3/hr) - /hr) /hr) /hr) /hr) VIQUA Standard 30 5 gpm (19 lpm) (1.1 9 gpm (34 lpm) (2.0 m 18 gpm (70 lpm) (4.2 m 24 gpm (91 lpm) (5.5 34 gpm (130 lpm) (7.8 mJ/cm...
  • Page 19 Specifications VH200 VH410 Model VH150 VP600 VP950 VH200-V* VH410-V* Maximum Operating 125 psi (861 kPa) 125 psi (861 kPa) 125 psi (861 kPa) 125 psi (861 kPa) 125 psi (861 kPa) Pressure Minimum Operating 15 psi (103 kPa) 15 psi (103 kPa)
  • Page 20 40 gpm (150 lpm) (9.0 m /hr) 60 gpm (230 lpm) (13.7 m /hr) @ 95% UVT VIQUA Standard 30 mJ/ 18 gpm (70 lpm) (4.2 m /hr) 24 gpm (91 lpm) (5.5 m /hr) 34 gpm (130 lpm) (7.8 m...
  • Page 21: Section 9 Manufacturer's Warranty

    VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.
  • Page 22 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com...