INSTALLATION REQUIREMENTS
1.1

CONDITIONS OF INSTALLATION

It is the law that all gas appliances are installed only by a CORGI Registered
Installer, in accordance with these installation instructions and the Gas Safety
(Installation and Use) Regulations 1998 as amended. Failure to install appliances
correctly could lead to prosecution. It is in your own interest and that of safety to
comply with the law.
The installation must also be in accordance with all relevant parts of the Local and
National Building Regulations where appropriate, the Building Regulations
(Scotland Consolidation) issued by the Scottish Development Department, and all
applicable requirements of the following British Standard Code of Practice.
1. B.S. 5871 Part 3 Installation of Decorative Fuel Effect Gas Fires
2. B.S. 6891 Installation of Gas Pipework
3. B.S. 5440 Parts 1 & 2 Installation of Flues and Ventilation
4. B.S. 1251 Open fire place components
5. B.S. 715 Metal flue pipes for gas appliances
6. B.S. 6461 Part 1 Installation of Chimneys and flues
7. B.S. E.N. 1858 Chinmeys Components & Concrete Flue Blocks
8. I.S. 813 : 1996 Domestic Gas Installation (Republic of Ireland)
No purpose made additional ventilation is normally required for this appli-
ance, when installed in G.B. When Installing in I.E. please consult document
I.S. 813 : 1996 Domestic Gas Installation, which is issued by the National
Standards Authority of Ireland. If installing in Northern Ireland, please
consult local building regulations. Any purpose made ventilation must be
checked periodically to ensure that it is free from obstruction.
1.2

FLUE AND CHIMNEY SUITABILITY

This appliance is designed for use with conventional brick built or lined chimneys
and fabricated flues. It is also suitable for use with pre-cast flue blocks conforming
to BS EN 1858 and metal flue boxes conforming to BS 715. All flues must
conform to the following minimum dimensions.
Minimum diameter of circular flues
Minimum effective height of all flue types
When fitting to conventional chimneys or 175mm flues it may be desirable to
fit the flue restrictor baffle (supplied) to reduce the flue flow and increase the
efficiency of the fire. Safe clearance of products must always be checked by
carrying out a smoke match test as described.
Supplied By www.heating spares.co Tel. 0161 620 6677
125 mm (Without Flue
Restrictor Fitted)
3 metres