ESAB Aristotig 405 AC/DC Instruction Manual page 11

Hide thumbs Also See for Aristotig 405 AC/DC:
Table of Contents

Advertisement

GB
23
Switch, pulse
welding/
normal
welding
24
Rotary switch,
ignition
current I1
Soft-Hot-Start
25
Rotary switch,
pulse time I2
26
Rotary switch,
welding
current I2
27
LED, welding
current I2
28
Rotary switch,
pulse time I4
29
Rotary switch,
final current I3
5.5.1
Error codes
Error
1
Primary
overcurrent
2
Primary
undervoltage
3
Primary
overvoltage
4
Over-
temperature
inlet/ outlet
vents blocked
5
Cooling water
disturbance
• Fast pulse
Pulse frequency in the range of 250 Hz to 5 Hz.
• Normal pulse
Pulse frequency in the range of 25 Hz to 0.5 Hz.
• Normal welding
Normal TIG welding without pulsation.
Rotary switch I1 determines the ignition behaviour for electrode and
TIG welding. It can be set as a percentage of the possible welding
current of the power supply.
Sets the current I2 pulse time.
Sets the welding current. The welding current can be set during
no-load operation and is shown in the 7 segment display.
LED illuminates, when the welding current I2 is active. During pulsed
operation: Toggles between the displays I2 and I4 with fixed pulse
frequency.
Sets the pulse time of the current I4.
Sets the final current I3.
Select a value so that no craters are caused.
Possible cause
Fault in power supply
Faulty power supply
Faulty fuses
Generator is
underdimensioned
The voltage used does not
comply with the rated volta-
ge
Exceeded allowed duty
cycle
Ambient temperature too
high
No water in cooling device
Defective or calcified switch
Water pump defective
- 83 -
Action
Call service
Check power supply
Use generator with sufficient power
Check power supply
Let device cool while running
Check air supply
Let device cool while running
Refill (Remember antifreeze!)
Install a new switch
Install a new pump

Hide quick links: