Instruction book
4.4

Electric cable size and fuses

Important
Fuses
Dryer
QED 650
QED 850
QED 1050
Electrical cable size
60 Hz CSA/UL - 40 ˚C (104 ˚F) variant
Dryer
QED 650
QED 850
QED 1050
4.5

Pictographs

Explanation of pictographs
Reference
1
2920 1818 00
Local regulations remain applicable if they are stricter than the values proposed.
For 60 Hz dryers, the settings of the main fuses below are according to CSA standards C22.2
Nos. 0; 0.4; 0.5; 0.12; 14; 68 and UL508. The cable size is valid for cable 90 ˚C (194 ˚F) at
an ambient temperature of 40 ˚C (104 ˚F).
Supply voltage
460 V
460 V
460 V
Supply voltage
460 V
460 V
460 V
Name
Disconnect from electrical supply before opening
Maximum fuses, recommended type: (CSA)
Class HRC Form II/(UL) Class K5 or RK5
(customer's installation)
3 x 20 A
3 x 20 A
3 x 25 A
Supply cable section, recommended
3 X AWG 12 + AWG 12
3 X AWG 12 + AWG 12
3 X AWG 10 + AWG 10