Quincy Compressor QED 650 Instruction And Maintenance Manual page 63

Refrigerant compressed air dryers
Hide thumbs Also See for QED 650:
Table of Contents

Advertisement

Menu icon, Test
Function
• To test the electronic water drain.
Procedure
Starting from the Main screen (see
• Move the cursor to the Menu action button and press the enter key (2); following screen appears:
• Using the scroll keys (1), move the cursor to the test icon (see above, section Menu icon)
• Press the enter key (2); following screen appears:
• A selection bar is covering the item drain test; press the enter key. A screen is shown to start draining or
to modify the manual drain time. Select the desired option and press the enter button (2).
• In case the drain test was chosen, the automatic drain will be opened for the time specified in the manual
drain time function.
• In case the manual drain time was chosen, a pop-up window appears. Use the up and down buttons (1)
to modify the value as required.