CONTROL PANEL GUIDE
®
AOYUE
8011
2
AUTOMATED HOT BAR
SOLDERING SYSTEM
AIR PRESSURE
CONTROL
1
+ + + +
- - - -
13
14
START
VAC
LEGEND:
1 — Pressure Adjustment Knob
2 — Pressure Gauge
3 — 8 pin camera input socket
4 — Brightness adjustment of Lower Lamp
5 — Brightness adjustment of Upper Lamp
6 — Temperature display.
"C" denotes actual Temperature, "c" Denotes Set Temperature
7 — Temperature Adjustment Buttons. "+" increase. "-" decrease.
8 — Timer Display
9 — Timer Adjustment Buttons."+" increase. "-" decrease.
10 — Mode Selection Button.
Green lamp –Automatic control. Red lamp– Manual control
11 — Hot Bar module Descend and Ascend Button.
For use only in Manual Control.
12 — Adjustment Platform In/Out Button. For use only in Manual Control.
13 , 16 — Start Automation Button.
14 — Reserved Button.
15 — Emergency Stop Button for use during Automatic control.
6
AUTO-
MATIC
TEMPERATURE
CONTROL
+
-
7
MANUAL
8
0010
CON-
TROL
10
TIMER
+
-
SELECT
9
11
BRIGHTNESS
ADJUSTMENT
UP
/
DOWN
MANUAL CONTROL
3
4
5
IN/ OUT
LOWER
UPPER
Camera
Input
12
16
15
EMERGENCY
START
4 4 4 4
OPERATING GUIDELINES
Please refer to the CONTROL PANEL GUIDE page for buttons and display
1.
INITIAL PROCEDURES
1. Make sure power switch (Located at the back of the unit) is turned
OFF before plugging the device to the main power source.
2. Switch ON the main power switch (Located at the back of the unit).
3.
Display panels, 6 and 8 will display "C100" and "0010" default
parameters.
2.
ADJUSTING PRESSURE
1. Adjust to desire pressure level using the Air pressure control Knob,
"1" from control panel guide. Pull on the knob to unlock it before
adjusting pressure level. Push knob back in to lock into place.
2. If Higher pressure is needed the pressure control knob located at
the left side of the unit can be adjusted for higher pressure level,
then use the Air pressure control Knob ("1"
guide) to fine adjust the pressure to desired level.
3.
ADJUSTING TEMPERATURE AND TIMER
1. During automated control mode. Green lamp lighted.
2. Adjust to desire temperature settings using the temperature control
buttons. ("7" from control panel guide).
3. The Temperature display window ("6" from control panel guide).
Will initially display a number with the Capital letter "C" at the
beginning. This indicates the number displayed is the actual
temperature. Upon pressing the temperature control buttons. The
display will change to small letter "c" indicating the temperature is
being set and the number shown is the current set temperature for
the Hot bar soldering tool.
4.
The heating element can be temporarily turned OFF and ON by
simultaneously pressing the "+" and "-" buttons of the temperature
adjustment buttons. The Display would show "OFF" to indicate the
heater is currently turned off.
panel directory.