PRODUCT DESCRIPTION
The 8011 Automated Hot Bar Soldering System is equipped
with a three way micro adjust system two Powerful magnified
camera and LCD screen for precise movement adjustment.
Its CPU controlled timer and temperature controls provide
precise timing and temperature stability. Finally its automated
pneumatic system provides accurate and easy repeatability .
SPECIFICATIONS
Main Station
Power input:
Station Dimensions:
Power consumption:
Temperature range:
Specifications are subject to change without prior notice
8
220V
400(w)x580(h)x580(d)mm
500W peak
100°C - 350°C
2 2 2 2
OPERATING GUIDELINES
7. Upon finishing one complete automated cycle the previously entered
temperature and timer settings will be saved to the CPU memory.
Note: The Emergency stop button can be used to stop the hot bar tool from
automatically descending. (see "Emergency stop button" for details)
5.
MANUAL CONTROL
1. Automatic or Manual Control can be selected by pressing the
SELECT button. ("10" from control panel guide).
2. When the RED Lamp is lighted it means the system is currently in
Manual control mode.
3. If the Green Lamp is lighted the system is in automatic control
mode, push the SELECT button to switch to manual control mode.
4. During the manual control mode the manual control buttons("11
and 12" from control panel guide) will be activated.
5. Pressing the In/Out button ("12"
control the platform movement.
6. Pressing the UP/Down button ("11" from control panel guide) will
control the Hot Bar Tool movement.
7. The Platform can only be controlled when the Hot bar tool is at the
up position.
6.
EMERGENCY STOP BUTTON
1. In case of immediate requirement to stop the automated soldering
cycle the Emergency Stop Button can be pushed. ("15"
control panel guide)
2. When emergency stop button is engaged the hot bar soldering tool
would move to the "up" position while the platform would move into
the "in" position. The system would be locked to manual control
mode.
3. The Platform and hot bar tool can then be manually adjusted to the
adequate position.
4. To disengage Emergency stop mode , unlock the Emergency stop
button by turning it clockwise.