System Output Ratings; Assigning Zones To Zone Expanders; Keypad Assignment; How To Assign Keypads - DSC PC1832 Reference Manual

Powerseries
Hide thumbs Also See for PC1832:
Table of Contents

Advertisement

Device
Description
FSA-410 xS/xST
4-wire Smoke Detector
FSA-410 xRS/
4-wire Smoke Detector
xRST/xLRST
PK5500
LCD Keypad
PK5501
ICON Keypad
PK5508
8 Zone LED Keypad
PK5516
16 Zone LED Keypad
RFK5500
LCD Keypad with Wireless Module
RFK5501
ICON Keypad with Wireless Module
RFK5508
8 Zone LED Keypad With Wireless
Module
RFK5516
16 Zone LED Keypad With Wireless
Module
LCD5500Z
LCD Keypad
LCD5501Z
ICON Keypad
LCD5501Z32-433
ICON Keypad with Wireless Module
LCD5511
ICON Keypad
LED5511
8 Zone LED Keypad
Skyroute
Cellemetry Communicator
PC5532Z
32 Zone LED Keypad
PC5516Z
16 Zone LED Keypad
PC5508Z
8 Zone LED Keypad
PC5100
Addressable Multiplexed Loop
Interface Module
PC5108
Zone Module
PC5132
Wireless Module
PC5200
Output Module
PC5204
Output Module
PC5208
Output Module
PC5320
Multiple Receiver Interface Module
Escort5580(TC)
Voice Prompting Module
PC5400
Printer Module
PC5401
Data Interface Module
PC5700
Fire Module
PC5900
Audio Verification Module
PC5904
Central Station Talk/Listen Module
PC5921
Intercom Audio Station
PC5921 EXT
Door Box Audio Station
PC5921 EXT/R
Door Box Audio Station
TL250
T-Link Ethernet Communicator
VVM110
Video Verification Module

System Output Ratings

Device
Output
Rating (12V
PC1616
AUX:
500mA (700 mA for UL/ULC).
Subtract the listed rating for each keypad,
PC1832
expansion module and accessory connected to
PC1864
AUX or Keybus.
BELL:
700 mA. Continuous Rating.
2.0 A. Short Term. Available only with standby
battery connected.
PC5200
AUX:
1.0 A.Continuous Rating. Subtract for each
device connected.
3.0 A. Short Term. Available only with stand-by
battery connected.
PC5204
AUX:
1.0 A. Continuous Rating. Subtract for each
device connected.
3.0 A. Short Term. Available only with stand-by
battery connected.
PC5208
AUX:
250 mA. Subtract for each device connected.
Subtract the total load on this terminal from the
PC1616/PC1832/PC1864 AUX/Keybus output.
PC5108
VAUX:
100 mA. Subtract for each device connected.
Subtract the total load on this terminal from the
PC1616/PC1832/PC1864 AUX/Keybus output.
Max Rating
@12V
DC
75mA
90mA
125mA
125mA
125mA
125mA
135mA
135mA
135mA
135mA
125mA
125mA
260mA
85mA
100mA
30mA
85mA
85mA
85mA
40mA
35mA
125mA
20mA
20mA
50mA
55mA
150mA
65mA
35mA
150mA
50mA
175mA
20mA
20mA
35mA
275mA
490mA
DC)
Other Devices
Read the manufacturer's literature carefully to determine the max-
imum current requirement (during activation or alarm) and use
this value for loading calculations. Do not allow connected
devices to exceed the system capabilities during any possible
operational mode.

2.6 Assigning Zones to Zone Expanders

The main panel contains zones 1 to 8. Additional zone expanders
may be added to increase the number of zones on the system.
Each zone expander consists of one group of 8 zones. Each
module must be set to assign the specific zones to the expander.
To do this, set the jumpers located on the expander to the proper
settings (see chart below).
NOTE:
PC5108 v1.0 and lower modules can only support the first
32 zones on the PC1616/PC1832/PC1864 system. PC5108 v1.0 and
lower, PC5700 enrolls as two expander modules.
NOTE:
Do not use PC5108 v1.0 and v2.0 simultaneously on the
same PC1616/PC1832/PC1864 panel.
NOTE:
Before a zone expander will work properly, you must set
the jumpers so the panel can determine the correct zone assign-
ment.
The following are jumper settings for different zone assignments
for PC5108 v2.0 modules. If you need to enroll PC5108 v1.0 or
PC5700 modules, refer to the appropriate module Installation
Sheet for the correct jumper settings.
Module Jumpers
J1
J2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
The following is a diagram of the PC5108 zone expander module
and where the jumper switches are located. Refer to the PC5108
Installation Instruction sheet for the module for more information.
NOTE:
Only jumpers J1, J2, and J3 determine the zone assign-
ment for the module.

2.7 Keypad Assignment

There are 8 available slots for keypads. LED and ICON keypads
by default are assigned to slot 1. LCD keypads are assigned by
default to slot 8. Keypads can each be assigned to a different slot
(1 to 8) which offers two advantages. The panel can supervise the
keypad connection to indicate a trouble condition if it is removed.
Also keypads can be assigned to operate on a specific partition,
or to operate as a global keypad.

How to Assign Keypads

1. Enter Installer Programming
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition and slot
assignment.
7
System Zones Assigned
J3
ON
Zones disabled
ON
Zones 09 - 16
ON
Zones 17 - 24
ON
Zones 25 - 32
OFF
Zones 33 - 40
OFF
Zones 41 - 48
OFF
Zones 49 - 56
OFF
Zones 57 - 64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc1864Pc1616

Table of Contents