Tenth System Option Codes - DSC PC1832 Reference Manual

Powerseries
Hide thumbs Also See for PC1832:
Table of Contents

Advertisement

[022] - Ninth System Option Codes
Option
Definition
1
Access Code
Required for [*][1],
[*][2], [*][3]
EN
2
Keypad Blanking
while Armed
EN
3
Auto-Arming/Force
Arming Open Zones
IMQ
4
Master Code
Bypasses Holdup
EN
5
Time Limit for PGM
05, 06, 17, 18
EN
6
RF Delinquency
Enable
7
Open Zones Cancel
Arming
EN
8
Audible Exit Delay
for Stay Arming

[023] - Tenth System Option Codes

Option
Definition
1
[F] Key Beeps
2
200 Baud Open/
Close Identifier
Toggle ON/OFF
3
Test Transmission
While Armed Only
4
Transmission
Counter
5
Stay/Away Toggle
Option
6
2-way Audio Discon-
nect
On/Off
Description
ON
Access code is required for [*][1], [*][2] and [*][3] menu options In order to access the [*][1] bypass
menu, [*][2] trouble menu, or [*][3] alarm memory menu a valid access code is required. Events will also be
generated and logged, thus identifying the user.
NOTE: You must have a version LCD5500 3.40U or greater keypad, PK55XX or RFK55XX Key-
pad.
NOTE: This feature is not supported by the PC5400.
OFF
No access code required for [*][1], [*][2], [*][3] menu options No access code is required In order to
access the [*][1] bypass menu, [*][2] trouble menu, or [*][3] alarm memory menu.
ON
Keypad Blanking while Armed Keypad will blank after the programmed time (Section [021], Option 3)
when the system is armed.
NOTE: This feature will only blank after exit delay has expired.
OFF
Keypad follow regular blanking option Keypad will blank after the programmed time (Section [021],
Option 3) when the system is armed or disarmed.
ON
Auto-Arming/Force Arming Open Zones All zones will be force armed during an autoarm regardless of
the force arm attribute on the zone.
OFF
Auto Arming follows Force Arming Attribute Only zones with the force arm attribute enabled will be
force armed during an autoarm.
ON
Master code bypasses holdup zones only Attempting to bypass a hold-up zone with any other access
code will generate error tone.
OFF
Any code can bypass hold up zones Any code can bypass Hold up zones
ON
Time Limit Enabled for PGM 05, 06, 17, 18 Setting Keypad Blanking Option ON - Option 5 Programming
Section [022] - may satisfy this requirement. The panel will turn off all lights and LCDs on the keypads if no
key is pressed for 30 or for 5 seconds – depending on the status of toggle option 3 in Programming Section
[021] irrespectively of the armed or disarmed state of the Intruder alarm system. Implementation of the
option 3 in Programming Section [021] shall allow the installer to enable/disable the 5 seconds time limit
for Programmable Output Options 05 (Armed Status), 06 (Ready to Arm), 17 (Away Armed Status) and 18
(Stay Armed Status).
OFF
Time Limit Disabled for PGM 05, 06, 17, 18 Listed PGM's will not turn off (time out)
ON
RF Delinquency Enabled If any wireless zone supervisory transmission is not received by the PC5132 dur-
ing a 15-minute period, the PC5132 will place the panel into Not Ready To Arm mode. In the armed state,
the Zone faults will generate tamper alarms. The panel will generate a silent trouble (NO trouble beeps but
the Trouble LED is turned ON) called "RF Device Delinquency", that's only viewable in [*][2] (Trouble Mem-
ory). The user can override the condition and arm the panel by using the feature.
OFF
RF Delinquency Disabled The system will not indicate an RF Delinquency when a zone supervisory trans-
mission is not received during a 15 minute period.
ON
Open Zones Cancel Arming If there is an open zone at the end of exit delay, arming of the system will be
canceled.
OFF
Open Zones Cancel Arming Disabled If there is an open zone at the end of exit delay the system will
arm with the zone open.
ON
Audible Exit Delay for Stay Arming When the system is armed in Stay mode the exit delay will be
sounded by 1 beep every 3 seconds.
OFF
Stay Arming is Silent When the system is armed in Stay mode the exit delay will be silent.
On/Off
Description
ON
[F] Key Beeps Only Whenever the [F] is pressed you will only get the acknowledge beeps from the key-
pad. The bell will not sound.
OFF
[F] Key Beeps and Sounds Bell [F] key will beep the keypad and trigger the bell output
ON
200 Baud Open/Close Identifier Toggle ON 200 Baud Open Close Identifier is 2 for arming 1 for disarm-
ing
OFF
200 Baud Open/Close Identifier Toggle OFF 200 Baud Open Close Identifier is 1 for arming 2 for dis-
arming
ON
Test Transmission While Armed Only The Panel will send a test transmission at the programmed interval
and time if the system is armed.
OFF
Test Transmission While Armed or Disarmed The Panel will always send a test transmission at the pro-
grammed interval and time.
ON
Transmission Counter in Hours The Panel will send a test transmission after the programmed number of
hours in the test transmission cycle (Section [377], Option 7)
OFF
Transmission Counter in Days The Panel will send a test transmission after the number of days pro-
grammed in the test transmission cycle (Section [377], Option 7) at the programmed time.
ON
Switching from Away to Stay Disabled The system can not be switched from Away to Stay mode by
pressing the [Stay] function key.
OFF
Away to Stay Toggle Option Permitted The system can be switched from Away to Stay mode by press-
ing the [Stay] Function key.
ON
2-way Audio Will Not Disconnect For New Event The system will not disconnect the 2-way audio ses-
sion if a new event occurs on the system.
OFF
2-way Audio Will Disconnect For a New Event The system will disconnect the 2-way audio session if a
new event occurs on the system.