Option
Definition
4
Remote Reset
UK
5
Engineer's Reset
UK
6
Disarming (WLS Key)
UK
7
Installer Access
Requires DLS win-
dow
EN
8
Arming Inhibit
EN
On/Off
Description
ON
Remote Reset Enabled. The purpose of this feature is to force the end user to contact the Installer/Cen-
tral Station whenever they have an alarm condition. This is accomplished by locking out the panel after an
alarm occurs, which will force the end user to call the Installer/Central Station to get a Reset code which
must be entered on the keypad before they will be able to use their system.
In the Armed state, when an Alarm occurs on a burglary zone (please refer to chart below), the system will
be locked out after disarming the panel. The panel will remain locked until a 4 digit Reset code that is pro-
vided by the Installer/Central Station is entered on a keypad. If the Duress code is used to disarm the parti-
tion, then the system will not be locked out. In the Disarmed state, only Audible 24Hr Burglary zones,
Audible 24Hr Latching Tamper zones, and Audible 24Hr zone on PGM 2 will cause the panel to be locked
out. To get the Reset code from the Installer/Central Station, the end user must provide the Installer/Central
Station with the corresponding System Lock code, displayed on the keypad.
The System Lock code will be randomly generated and displayed on the keypad after an alarm condition
when one of the following conditions occurs:
• the system has been disarmed (Duress Code excluded)
• the bell has timed out (24Hr zones - please see chart below)
• an access code has been entered (24Hr zones - please see chart below)
On a LCD keypad, the message "REMOTE RESET RQD" will be displayed on the top line and "CODE" along
with the actually code will be displayed across the bottom line.
On an LED keypad, the reset number will be scrolled across the keypad. Each digit will be displayed one at
a time for 1 second with a pause of 1 second between digits. There will be a 3 second pause after the last
digit of the System Lock code before the System Lock code is repeated. This routine will continue until the
Unlock code (from Installer/Central Station) is entered.
NOTE: While the system is locked out, the only options available are [*][3], [*][6], [*][7], and
[*][8]. Going into [*][8] Installers Programming while the panel is locked out will unlock the
panel. The system will continue to function properly (alarms, tampers, etc) while the system is
locked out. This feature will follow the Keypad Lockout . If the Duress Code is used to disarm
the system, the system will not be locked out. Silent 24Hr zone on PGM 2 will not Lock out the
panel. Lock out will follow both the Transmission and Bell Delays.
Zone Definition
00 Null Zone (Not Used)
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior Stay/Away
06 Delay Stay/Away
07 Delayed 24-Hr Fire
08 Standard 24-Hr Fire
09 24-Hr Supervisory
10 24-Hr Supervisory Buzzer
11 24-Hr Burg
12 24-Hr Holdup
13 24-Hr Gas
14 24-Hr Heat
15 24-Hr Medical
16 24-Hr Panic
17 24-Hr Emergency
18 24-Hr Sprinkler
19 24-Hr Waterflow
* These zones will lock out the system only if the zone is audible.
OFF
Remote Reset Disabled The system will not be locked out after an alarm occurs.
ON
Engineer's Reset Enabled If the panel has gone into alarm during the previous armed period, or if a 24
Hour alarm has occurred (armed or disarmed), the system will not be ready to arm (Ready Light OFF) until
the Installers Programming is entered or Engineer's Reset is performed via Downloading Software. This fea-
ture applies to Tampers and Faults in both Armed and Disarmed states and does not apply to Module
Tampers, System Supervisories, Zone Expander alarms or PGM2 Input Alarms.
OFF
Engineer's Reset Disabled If the panel has gone into alarm during the previous armed period, or if a 24
Hour alarm has occurred (armed or disarmed), the system will be ready to arm.
ON
Keyswitch Disarming During Entry Delay Only All key-switches and Wireless Keys on the system will
only disarm the panel if an entry delay is active.
OFF
No Entry Delay for Keyswitch Disarm All key-switches and Wireless Keys will disarm regardless if entry
delay is active or not.
ON
Installer Access follows DLS window Access to Installers programming requires the DLS window to be
opened up in order to access installers. Enable DLS window by entering [*][6][Access Code][5].
NOTE: For this feature to work section 401 option 2 must be enabled.
OFF
Installers can be accessed at any time Installers programming can be accessed at any time.
ON
Arming Inhibit for All Troubles When there is a trouble present on the system arming will be inhibited,
until the trouble is restored.
OFF
Troubles do not Inhibit Arming The system can be armed even when there is a trouble present.
Armed
Disarmed
Zone Definition
20 24 Hour Freeze
Lock
21 24 Hour Latching Tamper
Lock
22 Momentary Keyswitch Arm
Lock
23 Maintained Keyswitch Arm
Lock
24 Not Used
Lock
25 Interior Delay
Lock
26 24-Hr Non-Alarm
27 Delayed 24Hr Waterflow
28 Instant Waterflow
Lock
29 Auto Verify Fire
30 Fire Supervisory
Lock
Lock *
31 Day Zone
32 Instant, Stay-Away
33 Push to Set Zone
34 Final Door Set
35 24Hr Bell/Buzzer
36 24 Hour Non-Latching Tamper
37 Night Zone
87 Delayed 24 Hour Fire (Wireless)
88 Standard 24 Hour Fire (Wireless)
31
Armed
Disarmed
Lock
Lock *
Lock
Lock
Lock
Lock
Lock