The calculation of the Time of Day to call is carried out by genera-
tion of a pseudo-random time based on the Panel Identification
Code programmed in Section [404]. The time generated is
between 23:01 and 05:59. The first byte of the Panel ID Code is
used to generate the hour (the upper 5 bits are ignored). The
lower byte is used to generate the minute to call. The pro-
First Byte of Section [404]
xxxxx000
xxxxx001
xxxxx010
xxxxx011
Example 1: Section [404] = 5010
The First Byte = Hex 50 = Binary 0101 0000 = 23:xx
The Second Byte = Hex 10 = Decimal 16 = xx:16
Therefore, the time of day the Periodic Download occurs is =
23:16

[380] - First Communicator Option Codes

Option
Communicator Code
1
Communications
2
Restore Transmission
3
Dialing Method
4
Switch to Pulse Dialing
5
3rd Phone Number Enable
6
3rd Phone Number
7
For Future Use
8
Delinquency
Hour of Periodic DLS Call-up
23:xx
00:xx
01:xx
02:xx
On/Off
Description
ON
Communicator Enabled The system's communicator will be enabled and all events with reporting
codes will be reported to the monitoring station. Refer to the Telephone Number, Reporting Code
and Call Direction Programming Sections.
OFF
Communicator Disabled The system's communicator will be shut off and events will not be trans-
mitted to the monitoring station. Downloading may still be performed if enabled.
ON
Restore Transmissions on Bell-Time-out Zone restore reporting codes will not be transmitted
until the zone has been restored and the Bell cut-off time has expired. If the zone is not restored
when the bell cut-off time expires, the restore will be transmitted when the zone physically restores
or when the system is disarmed.
NOTE: 24-hour zones will not restore until the zone is physically restored.
OFF
Restore Transmissions Follow Zones Zone restore reporting codes will be transmitted when the
zone is physically restored. If the zones are still active when the system is disarmed, the restore codes
will be transmitted when the system is disarmed.
NOTE: 24-hour zones will not restore until the zone is physically restored.
ON
Pulse Dialing enabled The control panel will dial telephone numbers using pulse (rotary) dialing.
OFF
DTMF Dialing enabled The control panel will dial telephone numbers using DTMF (dual tone multi-
frequency) dialing.
ON
Switch to Pulse Dialing after 4 DTMF attempts If DTMF dialing is enabled, the control panel will
dial telephone numbers using DTMF dialing for the first 4 attempts. If unsuccessful, the control
panel will switch to pulse (rotary) dialing for the remaining attempts.
OFF
DTMF Dial for all Attempts If DTMF dialing is enabled, the control panel will dial telephone num-
bers using DTMF dialing for all dialing attempts.
ON
3rd Phone Number Enabled The 3rd Phone number will be used for Alternate Dialing with the 1st
Phone Number or as a Backup of the 1st Phone Number (see light 6).
OFF
3rd Phone Number Disabled The 3rd Phone number will not be used.
ON
Alternate Dialing Enabled (1st & 3rd) After each dialing attempt, the communicator switches
between the 1st Phone Number and 3rd Phone Number.
OFF
Call 1st Number, Backup to 3rd Number If the programmed number of attempts to communicate
to the First Telephone Number fail, The same number of attempts will be made to communicate to
the Third Telephone Number. If all attempts to communicate to the Third Telephone Number fail, a
Failure to Communicate Trouble will be generated.
ON
Delinquency Follows Zone Activity (Activity Delinquency) This feature assists in the monitoring
of the elderly and the handicapped. If there is no zone activity on a partition, the Delinquency Trans-
mission Delay timer in Section [377] will begin counting in hours. When the counter reaches the pro-
grammed time, the panel will communicate the Delinquency Code to the central station, if
programmed. If there is zone activity present on the system at any time, the counter will be reset. If
this option is used, the Closing Delinquency option is not available.
NOTE: This code will not be transmitted for partitions that are "Away" armed. Activity on
Bypassed zones does not affect this timer. The timer is reset on arming.
OFF
Delinquency Follows Arming (Closing Delinquency) This reporting code is sent whenever the
programmed number of days for Delinquency has expired without the partition being Armed. The
timer for this feature is programmed in Section [377]. The value programmed in this section deter-
mines the number of days the partition counts when not being armed before sending the Delin-
quency reporting code to the central station. Once this code is sent, the timer will not be started
again until the partition has been armed. Each day programmed in the counter represents one day
PLUS the time it takes for the partition to reach midnight. This feature may disabled by program-
ming 000 in Section [377].
grammed value is first converted to decimal (00 - 99). If the origi-
nal HEX value was greater than 99 in decimal it will rollover to 00
and continue (ex. %67 = 103 = 03). if the resultant is 59 or less
that value is used as the minute to call. If it is 60 or greater, 60 is
subtracted from it and the result is used as the minute to call (ex.
73 - 60 = 13).
First Byte of Section [404]
xxxxx100
xxxxx101
xxxxx110
xxxxx111
Example 2: Section [404] = 7234
The First Byte = Hex 72 = Binary 0111 0010 = 01:xx
The Second Byte = Hex 34 = Decimal 52 = xx:52
The time of day the Periodic Download occurs is = 01:52
NOTE:
The first call should occur 30 days after power up.
42
Hour of Periodic DLS Call-up
03:xx
04:xx
05:xx
05:xx