Using the dishwasher
CODE
CAUSE
IF01/Er01
The filling time has been exceeded without
the tank being filled.
The water stopcock is closed.
Er02
The tank temperature after filling is less
than the nominal value after a set period of
time. The machine must reach the correct
temperature in order for detergent mixing
to take place.
Er04
The temperature sensor in the booster
heater B41 is incorrect.
Er05
The temperature sensor in the tank B21 is
incorrect.
IF06/Er06
Water flow too low during final rinse.
The water stopcock is closed.
IF09
Alarm for changing the water.
Er12
The break tank (option) has not been filled
with water.
Er16
The rinsing temperature is too low before
final rinsing. The machine continues to the
rinsing phase but with a lower temperature
than set when the alarm is displayed.
Er17
The temperature in the booster heater is
too high for glass dishes (option). The ma-
chine continues to the rinsing phase but
with a higher temperature than set when
the alarm is displayed.
IF18
The machine is not emptying as it should.
IF30
Low water level in the washing tank before
the washing programme will start.
Er80
The pump contact is not installed properly.
The soft start does not work.
Er95
Alarm from external equipment.
Er96
The motor safety cut-out for the pump has
tripped.
WD-4S
ACTION
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
Open the stopcock.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
Contact an authorised service company.
Contact an authorised service company.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
Open the stopcock. Close the door.
Change the water. The alarm can be reset
by pressing ON/OFF on the panel.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
Open and close the door. The alarm can
be reset by pressing ON/OFF on the panel.
If the error recurs, contact an authorised
service company.
Contact an authorised service company.
The alarm can be reset by pressing ON/
OFF on the panel. If the error recurs, con-
tact an authorised service company.
Contact an authorised service company.
42
Rev. R1 (201509)