The floating switch contact is automatically switched off,
-
-
-
-
To activate the 'Energy-Manager' function, select 'E-Manager' and press the 'Enter' key.
When the 'Energy-Manager' function is running, the 'Energy-Manager' symbol will appear
in the top left corner of the display:
To deactivate the 'Energy-Manager' function, select a different function and press the 'En-
ter' key.
Notes on setting up the switch-on and switch-off points
If the difference between the switch-on and switch-off points is too small, or if there are fluc-
tuations in effective power, the result may be multiple switching cycles.
To avoid switching on and off frequently, the difference between the switch-on and switch-
off points should be at least 100 - 200 W.
When choosing the switch-off point the power consumption of the connected consumer
should be taken into account.
When choosing the switch-on point, the weather conditions and anticipated insolation
should also be taken into account.
Application example
Switch-on point = 2000 W, switch-off point = 1800 W
If the inverter is outputting 2000 W or above, then the floating switch contact on the inverter
is switched on.
If the inverter output falls to below 1800 W, the floating switch contact is switched off.
Possible applications:
operating a heat pump or an air-conditioning system using as much self-generated power
as possible

Time / date

Set the time, date and automatic changeover between summer and winter time
Setting range
Set time
Set the time (hh:mm:ss or hh:mm am/pm - depending on the setting in the time display for-
mat)
Set date
Set the date (dd.mm.yyyy or mm/dd/yyyy - depending on the setting in the date display for-
mat)
Time display format
for specifying the time display format
30
if the inverter is not feeding any power into the grid,
if the inverter is manually switched into standby mode,
if the effective power is < 10% of nominal output,
in the event of insufficient insolation.
when the floating NO contact is off (open contact)
when the floating NO contact is on (closed contact)
Set time / set date / time display format / date display format /
summer/winter time