Table Of Contents - IDEAL VANGUARD L 170 Installation And Servicing

Hide thumbs Also See for VANGUARD L 170:
Table of Contents

Advertisement

coNTENTS
Assembly.....................................................................15-23
Boiler clearances. .............................................................9
Burner connection. .........................................................24
commissioning and Testing. ................................. 28 & 29
Electrical connections. ...................................................25
fluing. ...............................................................................12
Gas Safety Regulations ...................................................4
Hydraulic Resistance. .......................................................2
Initial Start up Lighting. ..................................................29
Introduction. .......................................................................3
Installation. .......................................................................13
Performance Data. .............................................................2
Positioning of the Turbulators. ......................................28
Servicing. .........................................................................31
Ventilation. ....................................................................... 11
Water circulation. ..............................................................5
Water connections. ...........................................................6
Water System Requirements. ................................ 10 & 11
Water Treatment. ...............................................................5
Wiring Diagrams. .................................................... 25 & 26
cAuTIoN.
To avoid the possibility of injury during the installation, servicing or cleaning
of this appliance, care should be taken when handling edges of sheet steel components.
Vanguard L -
Installation & Servicing
GENERAL
Vanguard 'L'
Gas and fuel oil
PI No. 0461BN0658
Destination countries: GB, IE
INTRoDucTIoN
The Vanguard L boilers are a range of steel shell pressure jet
boilers offering high efficiency operation, ease of maintenance,
fuel flexibility and low emissions.
Suitable for oil or gas operation the Vanguard L range is supplied
in a choice of 18 standard models, rated in outputs from 130kW
(443,000 Btu/h) to 3500 kW (11,942,000 Btu/h). The range has a
maximum operation pressure of 6 bar.
Designed with a large combustion chamber that is positioned
in the lower part of the heat exchanger, the Vanguard L range
ensures maximum heat transfer efficiency (up to 92.5% net).
Through the use of an increased number of flue ways tubes
which are positioned in the hottest area of the heat exchanger
and constructed from a thicker steel construction than that
of traditional boilers, the Vanguard L range is capable of an
impressive output to size ratio.
Duty
The range of boiler is suitable for: combined indirect pumped
domestic hot water and central heating systems; independent
indirect pumped domestic hot water or central heating systems.
Fully pumped systems may be open vented or sealed.
The range of boilers is NOT suitable for:
1. Gravity DHW systems.
2. Gravity heating systems.
3. Direct domestic hot water supply.
3