Download Print this page

IDEAL Logic HIU 50 Indirect Product Manual

Logic hiu series

Advertisement

Quick Links

LOGIC HEAT
INTERFACE UNITS
(HIUs)
PRODUCT GUIDE
WE HAVE IT COVERED.

Advertisement

loading

Summary of Contents for IDEAL Logic HIU 50 Indirect

  • Page 1 LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE WE HAVE IT COVERED.
  • Page 2 Ideal Commercial Boilers is the UK’s market leader of high efficiency commercial heating solutions. Operating from its Hull manufacturing plant and offices since 1906, Ideal Commercial Boilers is one of the few true British manufacturers left in the heating industry. BRING BOILERS TO LIFE...
  • Page 3 HIU Introduction Logic HIU range Logic HIU 50 Indirect 10-13 Logic HIU 75 Indirect 14-17 Logic HIU 50 Direct MT 18-20 Logic HIU 50 Direct HT Metering & Accessories CF Echo II CF UltramaxX V Accessories Condensing Boiler range Evomax...
  • Page 4 LOGIC HIU INTRODUCTION TYPICAL SYSTEM The Ideal Heat Interface Units are heat energy transfer units. Designed for use in conjunction with centralised boilers, district heating or central energy systems. The function is to efficiently transfer heat from the plant room to the individual dwelling’s central heating (CH) and domestic hot water (DHW) systems.
  • Page 5 CIBSE. BENEFITS THE BENEFITS OF IDEAL LOGIC HIUs ARE: For information on how to design Ideal Logic HIUs into you next project please refer to the Design Guide which • Compact design requiring a minimum amount of space covers: •...
  • Page 6: Features And Benefits

    LOGIC HIU 50 INDIRECT The Logic heat interface unit is the latest ‘intelligent’ range of HIU from Ideal. The Logic HIU is the complete solution for instantaneous hot water production and space heating control. This is an indirect wall mounted HIU, providing 50 kW instantaneous priority DHW and 15 kW modulated CH.
  • Page 7 PRIMARY PERFORMANCE ELECTRICAL Maximum working pressure: 16 bar - primary Power supply 230 V (ac)±10% 50 Hz 3 bar - secondary Max. Power consumption 105 W Maximum temperature 85°C Protection class IP 40 Max. Percentage of glycol Actuator Stepper 24 V Max.
  • Page 8 Kv = 2.03 m³/h PRIMARY FLOW CHARACTERISTICS HYDRAULIC CHARACTERISTICS HEATING - PRIMARY SIDE 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s HEATING Kv = 2.03 m³/h Hydraulic Characteristics Heating - secondary side Kv = 2.63 m³/h 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s Hydraulic Characteristics...
  • Page 9 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s Hydraulic Characteristics Flow Path HYDRAULIC CHARACTERISTICS HEATING - SECONDARY SIDE Heating - secondary side Heating - secondary side Kv = 2.63 m³/h R R ESET ESET ON DHW DHW CH CH FA FAUL ULT T Flowrate -l/s...
  • Page 10 LOGIC HIU 75 INDIRECT The Logic heat interface unit is the latest ‘intelligent’ range of Logic HIUs from Ideal. The Logic HIU is the complete solution for instantaneous hot water production and space heating control. This is an indirect wall mounted HIU, providing 75 kW instantaneous priority DHW and 15 kW modulated CH.
  • Page 11 PRIMARY PERFORMANCE ELECTRICAL Maximum working pressure: 16 bar - primary Power supply 230 V (ac)±10% 50 Hz 3 bar - secondary Max. Power consumption 105 W Maximum temperature 85°C Protection class IP 40 Max. Percentage of glycol Actuator Stepper 24 V Max.
  • Page 12 Kv = 2.03 m³/h PRIMARY FLOW CHARACTERISTICS HYDRAULIC CHARACTERISTICS HEATING - PRIMARY SIDE 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s HEATING Kv = 2.03 m³/h Hydraulic Characteristics Heating - secondary side RESET ON DHW CH FAULT Kv = 2.63 m³/h 0.04 0.06 0.08 0.1 0.4 0.5...
  • Page 13 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s Hydraulic Characteristics Flow Path HYDRAULIC CHARACTERISTICS HEATING - SECONDARY SIDE Heating - secondary side Heating - secondary side Kv = 2.63 m³/h R R ESET ESET ON DHW DHW CH CH FA FAUL ULT T RESET...
  • Page 14 LOGIC HIU 50 DIRECT MEDIUM TEMP The Logic heat interface unit is the latest ‘intelligent’ range of Logic HIUs from Ideal. The Logic HIU is the complete solution for instantaneous hot water production and space heating control. This is a direct wall mounted HIU, providing 50 kW indirect instantaneous priority Domestic Hot Water (DHW).
  • Page 15 PRIMARY PERFORMANCE ELECTRICAL Maximum working pressure: 10 bar Power supply 230 V (ac)±10% 50 Hz Maximum temperature 85°C Max. Power consumption 105 W Max. Percentage of glycol Protection class IP 40 Max. Recommended primary 1.2 m³/h Actuator Stepper 24 V circuit flow rate Probes NTC 10 kΩ...
  • Page 16 Flowrate -l/s SATK 20203 - medium temperature unit - UPS 15-60 pump settings Kv = 2.12 m³/h PRIMARY FLOW CHARACTERISTICS Flowrate -l/s UPS 15 - 60 pump settings HYDRAULIC CHARACTERISTICS DOMESTIC HOT WATER - PRIMARY SIDE DHW - heat exchanger DOMESTIC HOT WATER Kv = 2.25 m³/h Flowrate -l/s...
  • Page 17 DOMESTIC HOT WATER OUTPUT 1,500 Primary flow temperatures 1,400 55˚C 60˚C 1,200 65˚C 70˚C 1,000 75˚C 1,500 Primary flow temperatures 80˚C 1,400 55˚C 85˚C 60˚C 1,200 65˚C 1,500 Primary flow temperatures 1,500 Primary flow temperatures 70˚C Primary flow temperatures 1,400 55˚C 1,400 1,000...
  • Page 18 LOGIC HIU 50 DIRECT HIGH TEMP The Logic heat interface unit is the latest ‘intelligent’ range of Logic HIUs from Ideal. The Logic HIU is the complete solution for instantaneous hot water production and space heating control. This is a direct wall mounted HIU, providing 50 kW indirect instantaneous priority Domestic Hot Water (DHW).
  • Page 19 PRIMARY PERFORMANCE ELECTRICAL Maximum working pressure: 10 bar Power supply 230 V (ac)±10% 50 Hz Maximum temperature 85°C Max. Power consumption 105 W Max. Percentage of glycol Protection class IP 40 Max. Recommended primary 1.2 m³/h Actuator Stepper 24 V circuit flow rate Probes NTC 10 kΩ...
  • Page 20 PRIMARY FLOW CHARACTERISTICS Flowrate -l/s UPS 15 - 60 pump settings HYDRAULIC CHARACTERISTICS DOMESTIC HOT WATER - PRIMARY SIDE DHW - heat exchanger DOMESTIC HOT WATER Kv = 2.25 m³/h 0.04 0.06 0.08 0.1 0.4 0.5 Flowrate - l/s DOMESTIC HOT WATER OUTPUT. 1,500 Primary flow temperatures 1,400...
  • Page 21 MID certified (Measuring instruments directive) • MBus + 1 water meter MODEL METER SALES CODE Logic HIU 75 Indirect 211346 Logic HIU 50 Indirect 211347 Factory fitted CF Echo 11 MBus 1 Logic HIU 50 Direct MT 211348 Logic HIU 50 Direct HT 211349 CF ULTRAMAXX V.
  • Page 22 CONDENSING COMMERCIAL BOILERS...
  • Page 23 • NOx <40mg/kWh (Class 5) for all natural gas models for maximum BREEAM points DOWNLOAD THE APP *5 year warranty subject to Terms and Conditions. 5 years parts and labour warranty available subject to being commissioned by Ideal Boilers.
  • Page 24: Available Options

    EVOMAX CASCADE FRAME & HEADER KITS BOILER FRAME AND HEADER KITS The Frame and Header Kits are suitable for modular (cascade) boiler installations, and are available up to a maximum output of 600 kW, in both in-line and back-to-back arrangements. IN-LINE KITS Kits include flow &...
  • Page 25 & pipe work connector, all isolation valves, pressure relief valve, drain cock and associated fittings • The Low Height Frame and Header Kit can be installed with either an Ideal Commercial Sequencer offering direct modulation of the system, reducing running costs, or a proprietary option •...
  • Page 26 IMAX XTRA 80 - 280kW The Imax Xtra range of condensing boilers is offered in six models with outputs from 80 to 280 kW suitable for floor standing application in either single or multiple applications. FEATURES & BENEFITS • Robust cast aluminium silicon alloy heat exchanger •...
  • Page 27 IMAX XTRA EL 320 - 1240kW The Imax Xtra EL range of condensing boilers is available in 10 models with outputs from 320 to 1240kW. Suitable for floor standing applications in either single or multiple installations. FEATURES & BENEFITS • Simple control interface with large backlit display •...
  • Page 28 EVOMOD 250 - 1000kW Available in 250, 500, 750 and 1000 kW modules, the Evomod will achieve an output up to 1MW from a single unit solution together with a minimum footprint that enables the product to be installed where space is limited. Each module provides a maximum of 250 kW heat output and will modulate down through a sophisticated control system.
  • Page 29 EVOJET 150 - 1450kW The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations. FEATURES & BENEFITS • Up to 109.3% part load efficiency •...
  • Page 30 COMMERCIAL RANGE OVERVIEW. CONDENSING BOILERS EVOMAX IMAX XTRA IMAX XTRA EL EVOMOD EVOJET • Floor Standing • Floor Standing • Floor Standing • Wall Hung • Floor Standing • Aluminium • Aluminium • Aluminium • Stainless Steel • Stainless Steel Alloy Heat Alloy Heat Alloy Heat...
  • Page 31: Models Available

    • Ultrasonic metering options available DOWNLOAD THE APP TYPICAL SYSTEM The Ideal Heat Interface Units are heat energy transfer units. Designed for use in conjunction with centralised boilers, district heating or central energy systems. The function is to efficiently transfer heat from the plant room to the individual dwelling’s central heating (CH)
  • Page 35: Need Help

    HERE FOR YOU. At Ideal, we are committed to delivering the highest levels of customer service. With over a century of experience in the heating industry, we know how important confidence and trust is to our customers. You can be confident to know that you’re partnering with a British manufacturer that’s supported by a dedicated national service team, delivering help and...
  • Page 36 Statutory rights of the consumer are not affected. PLEASE NOTE: The information in this brochure was correct at the time of going to print. Ideal Commercial Boilers reserve the right to make any modifications to product specifications or any other details, without prior notification. For further clarification, please enquire in writing to the head office address (address below).