Lts Series Specifications; Lts Series Packing List - Space-Ray LTU Series Installation And Operation Instructions Manual

Infrared radiant tube heater
Table of Contents

Advertisement

9.0)

LTS SERIES SPECIFICATIONS

Input, , , ,
Input
Input
Input
Btu/hr
Btu/hr
Btu/hr
Btu/hr
Model
Model
Model
Model
No.
No.
No.
No.
High
High
High
High
Low
Low
Low
Low
LTS 40
40,000
25,000
LTS 50
50,000
31,500
LTS 60
60,000
38,000 1-7/32" #42741020
LTS 75
75,000
50,000 1-7/16" #42741010
LTS 80
80,000
50,500
LTS 90
90,000
57,000
LTS 100 100,000 63,000
LTS 110 110,000 69,500
LTS 120 120,000 76,000
LTS 125 125,000 80,000
LTS 130 130,000 82,000
LTS 140 140,000 88,500 2-1/32" #42741090 5.5mm (0.216)
LTS 150 150,000 95,000 2-1/32" #42741090 5.7mm (0.224)
LTS 160 160,000 100,000 2-1/4" #42741100 5.8mm (0.228)
LTS 175 175,000 110,000 2-1/4" #42741100
LTS 180 180,000 114,000 2-1/4" #42741100
LTS 200 200,000 125,000 2-3/8" #42741130
LTS 225 225,000 146,000 2-1/2" #42741140 6.9mm (0.272)
LTS 250 250,000 162,000 2-3/4" #42741150
* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.
Type
Type
Type
Type
Gas Pipe
Gas Pipe
Gas Pipe
Gas Pipe
Gas
Gas
Connection
Connection
Gas
Gas
Connection
Connection
Natural
½" MPT
or Propane
(Male)
LTS 180-250: 6" round. See Section 17.0) for vent sizes and limitations.
1
Fuse
Fuse Rating:
Fuse
Fuse
In-line: 2 Amp 250V
(for 24V Circuit)
10.0)

LTS SERIES PACKING LIST

A. A. A. A. Control/Draft Inducer Package
Control/Draft Inducer Package
Control/Draft Inducer Package
Control/Draft Inducer Package
Part Description
Part Description
Part Description
Part Description
Control Box Assembly .............................................................................................................................. 1
Draft Inducer & Junction Box Assembly ................................................................................................ 1
Flue Restrictor Plate (See Section 9.0) for plate I.D. and part no.) ................................................... 1
4" x 6" Starting Collar
Control Fastener Kit (#42907010) ....................................................................................................... 1
Containing: #8-32 Screws & Nuts (#02166010 & #02127030) .......................................... 2
¼ - 20 Locknuts (#02167010) .............................................................................. 6
Tube Flange Gasket (#42921000) ...................................................................................................... 2
Installation & Operation Instructions (#43155040) .......................................................................... 1
Gas connector, 5/8" OD x 36"
4-inch Starting Collar (#40504020) supplied with LTS 40-175 models.
1
LTS 225 and 250 models using Gas Connector, 1" OD x 36" (#30302361)
2
Flue Restrictor Plate
Flue Restrictor
Flue Restrictor
Flue Restrictor
Plate
Plate
Plate
I.D. & Part #
I.D. &
I.D. &
I.D. &
Part #
Part #
Part #
1"
#42741040
1-1/8" #42741030 3.3mm (0.130)
1-1/2" #42741050
1-1/2" #42741050
1-5/8" #42741060
1-3/4" #42741070
1-3/4" #42741070 13/64 (0.203)
1-7/8" #42741080
1-7/8" #42741080
Tube
Tube
Tube
Tube
Flue
Flue
Flue
Flue
Diameter
Diameter
Connection
Connection
Diameter
Diameter
Connection
Connection
4"
4" Round
Rating:
Rating:
Rating:
1
(#42892009) Supplied with LTS 180-250 ................................................. 1
2
(#30302360) ................................................................................... 1
-16-
Orifice Size
Orifice Size
Orifice Size
Orifice Size
Natural Gas
Natural Gas
Natural Gas
Natural Gas
Propane Gas
Propane Gas
Propane Gas
Propane Gas
#31
(0.120)
#49
#46
#27
(0.144)
#43
#20
(0.161)
#39
#19
(0.166)
#38
#16
(0.177)
#36
#14
(0.182)
#33
#10
(0.194)
#31
1/8
#5
(0.206)
#30
#4
(0.209) 3.3mm (0.130)
#29
#28
#27
"C"
(0.242) 3.8mm (0.150)
"C"
(0.242)
#24
"F"
(0.257)
#21
#18
"K"
(0.281) 4.5mm (0.177)
Fresh Air
Fresh Air
Fresh Air
Fresh Air
Connection
Connection
1 1 1 1
Connection
Connection
120 Volt, 60Hz,
6" Round
Ignition System (direct spark):
Ignition System (direct spark):
Ignition System (direct spark):
Ignition System (direct spark):
30 second pre-purge period
Minimum *
Minimum *
Minimum *
Minimum *
Mounting Height
Mounting Height
Mounting Height
Mounting Height
@ @ @ @
@ @ @ @
Horizontal
Horizontal
Horizontal
Horizontal
45º Angle
45º Angle
45º Angle
45º Angle
(0.073)
10 ft.
9 ft.
(0.081)
11 ft.
10 ft.
(0.089)
12 ft.
11 ft.
(0.099)
13 ft.
12 ft.
(0.102)
13 ft.
12 ft.
(0.106)
13 ft.
12 ft.
(0.113)
13 ft.
12 ft.
(0.120)
14 ft.
13 ft.
(0.125)
14 ft.
13 ft.
(0.129)
14 ft.
13 ft.
14 ft.
13 ft.
(0.136)
15 ft.
14 ft.
(0.140)
15 ft.
14 ft.
(0.144)
15 ft.
14 ft.
15 ft.
14 ft.
(0.152)
18 ft.
17 ft.
(0.159)
18 ft.
17 ft.
(0.170)
20 ft.
19 ft.
20 ft.
19 ft.
Electrical
Electrical
Electrical
Electrical
Current
Current
Current
Current
Supply
Supply
Rating
Rating
Supply
Supply
Rating
Rating
1 Phase
2.6 Amp
QTY
QTY
QTY
QTY
Form #43155040
May 2013

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lts series