Ltu Series Specifications; Ltu Series Packing List - Space-Ray LTU Series Installation And Operation Instructions Manual

Infrared radiant tube heater
Table of Contents

Advertisement

6.0)

LTU SERIES SPECIFICATIONS

Input, , , ,
Input
Input
Input
Btu/hr
Btu/hr
Btu/hr
Btu/hr
Model
Model
Model
Model
No.
No.
No.
No.
High
High
High
High
Low
Low
Low
Low
LTU 80
80,000
50,500
LTU 90
90,000
57,000
LTU 100 100,000 63,000
LTU 110 110,000 69,500
LTU 120 120,000 76,000
LTU 125 125,000 80,000
LTU 130 130,000 82,000
LTU 140 140,000 88,500 2-1/32" #42741090 5.5mm (0.216)
LTU 150 150,000 95,000 2-1/32" #42741090 5.7mm (0.224)
LTU 160 160,000 100,000 2-1/4" #42741100 5.8mm (0.228)
LTU 175 175,000 110,000 2-1/4" #42741100
LTU 180 180,000 114,000 2-1/4" #42741100
LTU 200 200,000 125,000 2-3/8" #42741130
LTU 225 225,000 146,000 2-1/2" #42741140 6.9mm (0.272)
LTU 250 250,000 162,000 2-3/4" #42741150
* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.
Type
Type
Gas Pipe
Gas Pipe
Type
Type
Gas Pipe
Gas Pipe
Gas
Gas
Gas
Gas
Connection
Connection
Connection
Connection
Natural
½" MPT
or Propane
(Male)
1
LTU 180-250: 6" round. See Section 17.0) for vent sizes and limitations.
Fuse Rating:
Fuse
Fuse
Fuse
In-line: 2 Amp 250V
(for 24V Circuit)
7.0)

LTU SERIES PACKING LIST

A. A. A. A. Control/Draft Induce
Control/Draft Induce
Control/Draft Inducer Package
Control/Draft Induce
Part Description
Part Description
Part Description
Part Description
Control Box Assembly .............................................................................................................................. 1
Draft Inducer & Junction Box Assembly ................................................................................................ 1
Flue Restrictor Plate (See Section 6.0) for plate I.D. and part no.) ................................................... 1
4" x 6" Starting Collar
Control Fastener Kit (#42907010) ....................................................................................................... 1
Containing: #8-32 Screws & Nuts (#02166010 & #02127030) .......................................... 2
¼ - 20 Locknuts (#02167010) .............................................................................. 6
Tube Flange Gasket (#42921000) ...................................................................................................... 2
Installation & Operation Instructions (#43155040) .......................................................................... 1
Gas connector, 5/8" OD x 36"
1
4-inch Starting Collar (#40504020) supplied with LTU 80-175 models.
2
LTU 225 and 250 models using Gas Connector, 1" OD x 36" (#30302361).
Flue Restrictor
Flue Restrictor Plate
Flue Restrictor
Flue Restrictor
Plate
Plate
Plate
I.D. &
I.D. & Part #
I.D. &
I.D. &
Part #
Part #
Part #
1-1/2" #42741050
1-1/2" #42741050
1-5/8" #42741060
1-3/4" #42741070
1-3/4" #42741070 13/64 (0.203)
1-7/8" #42741080
1-7/8" #42741080
Tube
Tube
Tube
Tube
Diameter
Diameter
Diameter
Diameter
Connection
Connection
Connection
Connection
4"
4" Round
Rating:
Rating:
Rating:
r Package
r Package
r Package
1
(#42892009) Supplied with LTU 180-250 ................................................. 1
(#30302360) .................................................................................... 1
2
-6-
Orifice Size
Orifice Size
Orifice Size
Orifice Size
Natural Gas
Natural Gas
Natural Gas
Natural Gas
Propane Gas
Propane Gas
Propane Gas
Propane Gas
#19
(0.166)
#38
#16
(0.177)
#36
#14
(0.182)
#33
#10
(0.194)
#31
1/8
#5
(0.206)
#30
#4
(0.209) 3.3mm (0.130)
#29
#28
#27
"C"
(0.242) 3.8mm (0.150)
"C"
(0.242)
#24
"F"
(0.257)
#21
#18
"K"
(0.281) 4.5mm (0.177)
Flue
Flue
Fresh Air
Fresh Air
Flue
Flue
Fresh Air
Fresh Air
1 1 1 1
Connection
Connection
Connection
Connection
6" Round
Ignition Syste
Ignition Syste
Ignition Syste
Ignition System (direct spark):
30 second pre-purge period
Minimum *
Minimum *
Minimum *
Minimum *
Mounting Height
Mounting Height
Mounting Height
Mounting Height
@ @ @ @
Horizontal
Horizontal
Horizontal
Horizontal
45º Angle
45º Angle
45º Angle
45º Angle
(0.102)
13 ft.
12 ft.
(0.106)
13 ft.
12 ft.
(0.113)
13 ft.
12 ft.
(0.120)
14 ft.
13 ft.
(0.125)
14 ft.
13 ft.
(0.129)
14 ft.
13 ft.
14 ft.
13 ft.
(0.136)
15 ft.
14 ft.
(0.140)
15 ft.
14 ft.
(0.144)
15 ft.
14 ft.
15 ft.
14 ft.
(0.152)
18 ft.
17 ft.
(0.159)
18 ft.
17 ft.
(0.170)
20 ft.
19 ft.
20 ft.
19 ft.
Electrical
Electrical
Current
Current
Electrical
Electrical
Current
Current
Supply
Supply
Supply
Supply
Rating
Rating
Rating
Rating
120 Volt, 60Hz,
1 Phase
2.6 Amp
m (direct spark):
m (direct spark):
m (direct spark):
QTY
QTY
QTY
QTY
Form #43155040
May 2013
@ @ @ @

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lts series

Table of Contents