Reinstalling An Expansion Enclosure - IBM System x iDataPlex dx360 M3 User Manual

Types 6313, 6385, 6386, and 6391
Table of Contents

Advertisement

2. Pivot the cover to the closed position until it clicks into place.
3. Install the system-board tray in the chassis (see "Reinstalling a system-board

Reinstalling an expansion enclosure

Attention:
cover is installed and closed or an expansion enclosure is installed. Do not attempt
to override this protection.
To reinstall an expansion enclosure, complete the following steps:
1. Orient the expansion enclosure above the system-board tray.
2. Lower the expansion enclosure so that the pins at the rear slide down into the
3. If you disconnected cables when you removed the enclosure, reconnect them.
4. Pivot the expansion enclosure down onto the system-board tray until it clicks
5. Install the system-board tray in the chassis (see "Reinstalling a system-board
46
System x iDataPlex dx360 M3: User's Guide
components are installed and seated correctly, all internal cables are correctly
routed, and you have not left loose tools or parts inside the system-board tray.
tray in a 2U chassis" on page 47 or "Reinstalling a system-board tray in a 3U
chassis" on page 48).
You cannot install the system-board tray into the chassis until the
Expansion
enclosure
slots at the rear of the system-board tray. Before you close the cover, make
sure that all components are installed and seated correctly, all internal cables
are correctly routed, and you have not left loose tools or parts inside the
system-board tray.
into place.
tray in a 2U chassis" on page 47).
System-board
tray

Advertisement

Table of Contents
loading

Table of Contents