eka EKF 711UD–EKF 664UD–EKF 664 UD-HTEKF 664 UD/003 Use And Instruction Manual Use And Instruction Manual page 12

Table of Contents

Advertisement

TECNOEKA Srl ______________________________________________________________ use and instruction manual
Changing the door seal - The door seal has a rigid profile with 3 fixing tabs. The profile must be
Changing the door seal
Changing the door seal
Changing the door seal
fitted into the guide on the face of the cooking chamber. The rectangular seal fits perfectly into
the frame of the guide and, therefore, the seal profile fits perfectly onto the face of the cooking
chamber. To change the seal, remove the old one from the guide by pulling hard at the four
corners. Clean any dirt from the guide and introduce the new seal (to make this operation
easier, we advise dampening the seal profile with soapy water).
Resetting the thermal breaker safety device - This device is reached by removing the left side of
Resetting the thermal breaker safety device
Resetting the thermal breaker safety device
Resetting the thermal breaker safety device
the appliance and can be reset by pressing the red key right down (which is marked by a special
adhesive label), which is inside the electric components compartment.
Possible faults
Possible faults
Possible faults
Possible faults
Type of fault
Type of fault
Type of fault
Type of fault
Control panel
completely off (the oven
does not work)
Cooking cycle set: the
oven does not work
Automatic humidifier
ON: no steam is
produced in the cooking
chamber
Door closed: steam
comes out of the seal
The oven does not cook
evenly
Lighting lamp in the
cooking chamber does
not work
The thermo safety
device turns on in
continuous
page 12 __________________________________________________________________________________________
Cause
Cause
Cause
Cause
- Incorrect electric connections to the
mains
- No mains voltage
- Thermal break safety device tripped
- Door open or ajar
- Damaged magnetic sensor
- Incorrect
connection
mains
- Cut-off cock closed
- Blocked water inlet filter
- Damaged water inlet solenoid
- Seal not fitted correctly
- Damaged seal
- Handle prong loosened
- One of the motors is blocked or
turns slowly
- The motors do not go into reverse
- Heating element not powered or is
damaged
- Damaged lamp
- Damaged lamp feeder
- Device damaged
- Regulating thermo state damaged
- Check the mains connection
- Restore mains voltage
- Reset the thermal break safety
device
- Close the door
- Contact a qualified technician to
repair the sensor
to
water
- Check the connection to water
mains
- Check the cut-off cock
- Clean the filter
- Contact a qualified technician to
repair the solenoid
- Check the seal fitting
- Contact a qualified technician to
repair the seal
- Contact a qualified technician to
repair the prong
- Contact a qualified technician to
repair the motor
- Contact a qualified technician to
repair the motor
- Contact a qualified technician to
repair the element
- Change the lamp
- Contact a qualified technician to
repair the feeder
- Contact a qualified technician to
repair the feeder
- Contact a qualified technician to
repair the feeder
Corrective action
Corrective action
Corrective action
Corrective action

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKF 711UD–EKF 664UD–EKF 664 UD-HTEKF 664 UD/003 and is the answer not in the manual?

This manual is also suitable for:

Ekf 664 ud/003Ekf 616 uEkf 616 ud-ht

Table of Contents