23. Continue to follow the screen instructions until you receive a message that the replacement is
successful. Successful replacement is indicated by the OK message displayed next to the Command
field at the top of the screen.
24. Press the F3 key to return to the PCI Hot-Plug Manager menu.
25. Select Install/Configure Devices Added After IPL and press Enter. Then follow the instructions on
the screen. Successful replacement is indicated by the OK message displayed next to the Command
field at the top of the screen.
26. If you do not have other adapters to replace, continue with the next step.
OR
If you have other adapters to replace, press the F3 key to return to the PCI Hot-Plug Manager menu
and then return to step 13 on page 53.
27. Press F10 to exit the Hot-Plug Manager.
If you have added, removed, or replaced any adapters, run the diag -a command. If the system
responds with a menu or prompt, follow the instructions to complete the device configuration.
Removing a Hot-Pluggable PCI Adapter: If you are permanently removing an adapter from a system, this
procedure should be used.
Attention:
The Linux operating system does not support these hot-plug procedures. Also, Linux does not
support hot-plugging any hot-pluggable PCI adapters. Systems with Linux installed on one or more
partitions must be shut down and powered off before replacing any PCI adapter assigned to a Linux
partition. Follow the non-hot-pluggable adapter procedures when replacing a PCI adapter in any partition
with Linux installed.
Note: If you are removing an adapter and replacing it with an adapter that is identical to the adapter that
was removed, use the "Removing and Replacing a Hot-Pluggable PCI Adapter" on page 53
procedure.
To remove an adapter, perform the following steps:
1. Open the door of the rack.
2. Determine the slot from which you are removing the adapter.
3. Ensure that any processes or applications that might use the adapter are stopped.
Note: Removing a hot-pluggable PCI adapter requires the system administrator to take the PCI
adapter offline before performing any PCI adapter hot-plug procedures. Before taking an
adapter offline, the devices attached to the adapter must also be taken offline as well. This
action prevents a service representative or user from causing an unexpected outage for
system users.
For more information on taking the PCI adapter online, see the AIX operating system
documentation. Documentation for the AIX operating system is available from the IBM
Eserver pSeries Information Center at
http://publib16.boulder.ibm.com/pseries/en_US/infocenter/base. Select AIX documentation.
The AIX Documentation CD contains the base set of publications for the operating system,
including system-management and end-user documentation.