D10 Power Supply

Before performing the following procedure, read the "Safety Considerations" on page 41.
Removal
Attention:
Do not remove two power supplies at the same time if performing hot-plug procedures. Power
supplies are considered as hot-pluggable FRUs only if you remove one power supply at a time. The power
supplies can be removed from the front of the I/O subsystem.
1. Disconnect the power cord from the power supply.
2. Unlatch the power supply handle and rotate the handle downward to unseat the power supply.
Attention:
Do not remove a power supply for more than four minutes. If you cannot replace the
power supply in less than four minutes, shut down the system and then remove the power supply.
3. Pull the power supply straight out from the I/O subsystem.
Replacement
To replace the power supply, perform the steps in the removal procedure in reverse order.