To flip the LED display for better readability in any mounting situation, do the following:
1.
Press <MODE/ESC> repeatedly until diS or rdiS shows on the display.
2.
Press <UP> or <DOWN> to select diS (normal display mode) or rdiS (inverse
display mode).
3.
Press <ENTER>.
The Master/Slave mode allows a single Intimidator Beam LED 350 unit (the master) to
control the actions of one or more Intimidator Beam LED 350 units (the slaves) without
the need of a DMX controller. The master unit will be set to operate in either Automatic
or Sound-Active mode, while the slave units will be set to operate in Slave mode. Once
set and connected, the slave units will operate in unison with the master unit.
Configure the units as indicated below.
Slave units:
1.
Press <MODE/ESC> repeatedly until one of the following shows on the display:
nASL, nAFA, nStS, SLAv
2.
Press <UP> or <DOWN> to select SLAv.
3.
Press <ENTER> to accept and Son shows on the display.
4.
Set the DMX address to d001.
5.
Connect the DMX input of the first slave unit to the DMX output of the master unit.
6.
Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
7.
Finish setting and connecting all the slave units.
Master unit:
1.
Set the master unit to operate in either Automatic or Sound-Active mode.
2.
Make the master unit the first unit in the DMX daisy chain.
To increase or decrease movement speed, do the following.
1.
Press <MODE/ESC> repeatedly until nouS shows on the display.
2.
Press <ENTER> and inS or dES shows on the display.
3.
Press <UP> or <DOWN> to select inS (increasing speed) or dES (decreasing
speed).
4.
Press <ENTER>.
·
Configure all the slave units before connecting the master unit to the DMX
daisy chain.
·
Never connect a DMX controller to a DMX string configured for Master/Slave
operation because the controller may interfere with the signals from the
master unit.
·
Do not connect more than 31 slave units to the master unit.
·
The Intimidator Beam LED 350 can be connected in Master/Slave with the
Intimidator Spot LED 350, but the Intimidator Beam LED 350 must be set to
Automatic mode's slow program for the products to sync correctly.
·
Do not change the Movement Speed on the Intimidator Beam LED 350 while
the product is in motion. Stop the product before changing speeds.
To reset the software, do the following:
1.
Press <MODE/ESC> repeatedly until rESt shows on the display.
2.
Press <ENTER>. The product will reset all settings in the software to the default
factory settings.