Code
Mode
555
RCV ECM
570
RCV
571
XMT
580
XMT
581
XMT
601
XMT
623
XMT
630 XMT or RCV
(Polling)
631
XMT
634
XMT
638
XMT
800
Relay
Comm.
815
816 Conf. Polled
825
Conf. RCV
Conf. Polled
870
MEM XMT
Multi-Copy
880
-
884
-
Fax Information Codes
Phase
Description of Problem
D
Transmitted PIN after receiving
EOR.
B
Password or machine code did not
match during remote diagnostic
communication.
B
Remote unit did not have the
remote diagnostic function.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
ADF Door was opened during ADF
transmission.
A
No original was in the ADF. (Built-
in dialer engaged)
B
Redial count over.
A
"STOP" button was pressed during
Auto Dialing.
B
Redial count over with no response
or busy tone was not detected.
Note:
U.S.A. and Canadian models
will redial only once if a busy
tone is not detected.
Power turned off with applicable
data in memory or during
communication.
The machine was requested to
relay a document but has no Relay
Hub capability.
Mailbox is full.
"The received Polling Password
did not match. The machine does
not have Confidential Comm.
capability."
Parameter settings of the initial
sending station are not properly
set.
Memory overflow occurred while
storing documents into memory.
-
File Access Error.
-
File Access Error.
Line is faulty and Operator Call
requested by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
No dial tone detected. Sensor dial tone
is not detected. (destination dependent)
Busy tone is detected. (destination
dependent) T1 timer (35±5 sec.)
elapsed without a signal from the
receiver.
Telephone line cable is disconnected.
Wrong number is dialed.
SC or MJR PCB is abnormal.
Power switched off. Power failure
occurred.