Bevel Arrow Adjustment; Changing The Saw Blade - Steel City 35920 User Manual

10" granite cabinet saw
Table of Contents

Advertisement

Fig. 25
1. To align the blade parallel to the miter slot, first loosen
two hex head screws (A) under the left side of the
table saw. This is the same side as the bevel
.
handwheel (B)
SEE FIG 25.
Fig. 26
2. Open motor cover located on the right side of the
table saw. Loosen two hex head screws (C) located
directly above the opening.
3. The saw table is now loose and can be repositioned
until the blade is parallel to the miter slot. Repeat
steps in "CHECKING BLADE ALIGNMENT."
4. When blade is parallel to miter slot, tighten all four
hex head screws.
5. Recheck blade alignment.
6. Tilt the blade to 45 degrees, and rotate the saw blade
by hand. Make sure the blade does not contact the
table insert.
SEE FIG 26.

BEVEL ARROW ADJUSTMENT

1. Make certain that the blade is at 90-degrees to the
Table surface with a combination square.
Fig. 27
2. Check that the bevel arrow is pointing to the zero
degree mark on the bevel scale located on the front
of the cabinet.
SEE FIG 27.
3. To adjust arrow, loosen the Philips head screw (A),
and reposition the bevel arrow and tighten screw.

CHANGING THE SAW BLADE

Fig. 28
1. Remove the table insert retaining bolt and remove the
Table insert.
24