Sentex SW2200 Installation Instructions Manual page 7

Swing gate operator
Table of Contents

Advertisement

PROGRAMMING
Programming is accomplished with a 5 button, 2 LED membrane switch located on
top of the control box. Programming instructions are presented on a 2 row, 16
character LCD screen (see Figure 2).
DEVICE CONNECTIONS
Connections are made to the lower half (exposed half) of the front panel PCB.
Provisions are made for:
J2 – Safety edge open (trailing edge contact
sensor); N/O & N/C
J3 – Safety edge close (leading edge contact
sensor); N/O & N/C
J4 – 3 loop detectors
J5 – Close; Open w/ Timer
J6 – Not Used
J7 – Stop (required N/C connection)
Figure 1
Sentexsystems
01-16169F1
Figure 2
J8 – Hold open (no timer); Single Button
J9 – Photo eye (non-contact sensor); N/O
& N/C Contacts
JP5, JP6, JP7, & JP8 – Output relays for
JP5, JP6, JP7 – Master/Slave connections
JP9 – 24 VDC power
JP12 – 24 VAC power
JP14 – 115 VAC power