Troubleshooting

Troubleshooting

Diagnostic Screen

The Diagnostic Screen is real-time screen displaying critical information for
troubleshooting the operator. Refer to Figure 21.
RELATIVE POSITION
This shows the position using the
passpoint as a zero reference. Each
value represents one hall effect count
or 1/12 of a motor revolution. This
value can be 4500 or higher.
COMMAND SPEED
The command velocity of the
processor, 0-222 max.
OPERATOR STATE
Shows the 5 stages of operation:
Open, Opening, Midstop, Close and
Closing.
HALL EFFECT
Symbol switches when hall sensor
trips > <.
TQ
Displays relative torque of the
operator.
PASSPOINT FLAG
"P" flashes upon seeing the passpoint.
"D" states that the entrapment is
disabled.
Doc 01-G0181
Rev A
ENTRAPMENT MODE:
T = Normal torque measurement.
E = Indicates overtorque entrapment
has occurred.
P = Indicates a position entrapment
has occurred.
TQ LIMIT
Self adjusting limit that triggers TQ
entrapment. This value is different for
ramp up and ramp down and run.
LIMIT ACCURACY
This number represents the operator
and position relative to the open or
close limit. This number should be in
the range of +/- 10. The number will
be replaced by "**" if the operator and
position deviates by more than 20
counts.
ENTRAPMENT LEVEL
This represents the number of times
the operator has detected
entrapment.
Figure 21
01-G0181F20