Basic Setup and Device Connections

Device Connections

All electrical connections are made with a euro-connector for quick and easy
maintenance of the electrical box. You may make 95% of all accessory connections
with 18-24 gauge wire. Accessory power should be 16-18 gauge.
NOTE: Connect line power to the electrical box according to the instructions on
page 6.
NC (normally closed) terminals are required. That is, you must either connect them for
use or jumper them (non-use). The operator will not run without the NC terminals wired
to an NC device or otherwise shorted. These terminals are identified by safety bars
(see Figure 20).
J7 = STOP
J2 = SE OPEN (Safety Edge Open)
J3 = SE CLOSED (Safety Edge Closed)
J9 = PHOTO EYES
Figure 20
Doc 01-G0181
Rev A
01-G0181F19