Pin Connector Charts

18-Pin Connector (P1)

Pin Number
Wire Colour
1
WHITE/BLUE
2
PINK/BLACK
3
VIOLET/WHITE
4
GREY/BLACK
5
BROWN
6
RED/WHITE
7
8
9
10
WHITE
11
BLACK with WHITE TAG
12
WHITE
13
BLUE/BLACK
14
VIOLET
15
BROWN/BLACK
16
WHITE/BLACK
17
VIOLET/BLACK
18
GREEN/BLACK
WHITE/BLUE Channel 4 Accessory (-) Output (P1/1)
CAUTION: Do not use this output to roll-up windows on vehicles not equipped with "Total-close."
The WHITE/BLUE wire can be programmed to provide a (-) output from one second to two minutes. The wire can
also be programmed to automatically activate when the alarm system is armed. This output can be used to acti-
vate headlights, roll-up/down windows and close sunroofs on vehicles equipped with factory "Total-close."
PINK/BLACK Second Stage Unlock (-) Output (P1/2)
The alarm has onboard relays to lock and unlock the doors. It also incorporates a PINK/BLACK (-) output wire
that will allow the customer to operate a Two-Stage Unlock feature. The second stage unlock wire provides a 400
mA, 0.75 second (-) output when activated.
CAUTION: Ask the customer at the time of installation whether they require this feature. Verify the
type of central locking system the vehicle has. Carefully follow the door lock/unlock diagrams on
pages 13-17.
6
Description
Channel 4 Accessory (-) Pulsed or Timed Output
Second Stage Unlock (-) Output
Arm/Disarm (-) Output (300mA maximum)
Channel 5 Accessory (-) Pulsed or Latched Output
Coded Link for Siren
Channel 2 Accessory (-) Pulsed for Boot Release
Pre-Wired to Ultrasonic Sensors
Indicator Light Output
Indicator Light Polarity (+) or (-) Input Select
Indicator Light Output
Unlock Common
Unlock Normally Open
Unlock Normally Closed
Lock Normally Closed
Lock Normally Open
Lock Common
©