Cabinet and Countertop Layout

WARNING
To reduce the risk of personal injury caused by
reaching over a hot appliance, avoid locating cabinet
storage space directly above the cooktop.
Failure to meet or exceed the maximum and mini-
mum dimensions/clearances stated in these instruc-
tions may result in a fire hazard.
Follow the countertop manufacturer's instructions
regarding the minimum corner radius, use of heat
reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor downdraft vent.
All tolerances +1/16" (+1.6 mm), -0
unless otherwise noted.
Combustible overhead
cabinets
3
13" max.
(33.0 cm)
30" min.
Combustible
(76.2 cm)
surface to rear
See cutout
dimensions
1
Measured from the cooking surface (top of cooktop grate).
2
If installing with an overhead vent hood, also check the hood
specifications for minimum required clearances.
3
Not applicable for cabinets more than a horizontal distance of
6" (15.2 cm) from edge of cooktop for RGC304, 5 1/2" (14.0 cm)
for RGC365. Allow 7 1/2" (19.1 cm) from cutout edge for RGC304,
7" (17.8 cm) for RGC365.
Minimum Required Clearances Around the Cooktop
Model
(A) Minimum
RGC304
30" (76.2 cm)
RGC365
36" (91.4 cm)
6
Installation Specifications
A
1, 3
18" min.
(45.7 cm)
1, 2
1 7/8" min.
(4.8 cm)
See cutout dimensions
(A) Recommended
36" (91.4 cm)
42" (106.7 cm)
Allow a minimum 1/4" (6 mm) clearance between the
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed
below the cooktop.
B
Under Cabinet Clearances
Model
RGC304
RGC365
* To allow clearance for hold down brackets
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere
with the cooktop when it is installed. If installing another
appliance in the cabinet below, allow for the routing of
gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when
the unit is installed.
Access to the electrical outlet when the cooktop is in
place. The 40" (101.6 cm) power cord must be able to
reach the electrical outlet.
Access to the underside of the cooktop for service and
inspection purposes.
Clearance inside the cabinet to allow for proper hold
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
Downdraft Vent Compatibility
If installing the cooktop with a downdraft vent, install only
the approved Dacor model numbers specified below:
Cooktop Models
Approved Downdraft Vent Models
RGC304
ERV30, ERV3015, PRV30 or RV30
RGC365
ERV36, ERV3615, PRV36 or RV36
1/4" (6 mm)
min. clearance
to combustible
surfaces
(B) Minimum*
29" (73.7 cm)
35 1/4" (89.5 cm)