Cabinet and Countertop Layout

• To reduce risk of personal injury from reaching over a hot cooktop,
avoid cabinet storage over the cooktop.
• Failure to meet or exceed the maximum and minimum dimensions/
clearances as instructed may cause a fire hazard.
• Follow the countertop manufacturer's instructions regarding all
aspects of countertop installation.
• Carefully check the cooktop installation site. Situate the
cooktop away from drafts and wet areas.
• Use the cooktop with a suitable vent hood or approved Dacor
downdraft.
B
Underneath Cabinet Dimensions
Model
(B) Minimum for clearance of hold-down brackets
HDCT304
HDCT365
Installation must allow:
• At least 1/4" (6 mm) clearance between the bottom of the
cooktop chassis and all combustible surfaces, including the
edges and corners of drawers under the cooktop.
• Clearance for hold-down brackets
• The gas supply piping, gas shut-off valve, and electrical outlet
must not interfere with the installed cooktop.
• If installing an appliance below the cooktop, allow for routing of
utilities behind it.
• Access to the gas shut-off valve and regulator without moving
the cooktop.
• The 40" (101.6 cm) power cord to reach an electrical outlet, and
outlet to be accessable without moving the cooktop.
• Access to the cooktop bottom for service/maintenance (Do not
install fixed shelving below the cooktop).
All specifications subject to change without notice.
Heritage
®
WARNING
1/4" (6 mm)
min. height clearance
to combustible
surfaces
29 in (73.7 cm)
35 1/4 in (89.5 cm)
30", 36" Dual Cooktop
Model
HPCT304G
HPCT365G
Combustible overhead
cabinets
13" max.
(33.0 cm)
Combustible
surface to rear
See cutout
dimensions
1 Measured from the cooking surface (top of cooktop grate)
Callout
2 If installing with an overhead vent hood, check the hood
installation instructions for specifications for minimum req
1
Measured from top of cooktop grate
3
Not required if side cabinets are 6 inches more than the left
If installing with an overhead vent hood, also check hood
of the cooktop. For DYGCT304, it is 5 1/2 inches (14.0 cm)
2
specifications for minimum required clearances.
for DYGCT365. Allow 7 1/2" (19.1 cm) from cutout edge for
7" (17.8 cm) for DYGCT365.
Not applicable for cabinets more than a horizontal distance
3
of 6" (15.2 cm) from edge of cooktop.

Downdraft Compatibility

If installing the cooktop with a downdraft, use only the approved
Dacor model numbers MRV3015 or MRV3615. (See Pg. 5.)
Model
HDCT304
HDCT365
www.dacor.com
All tolerances: ±¹/₁₆" (±1.6 mm) unless otherwise stated.
PLANNING
(A) Minimum
30" (76.2 cm)
36" (91.4 cm)
A
1, 2
30" min.
(76.2 cm)
1 7/8" min.
(4.8 cm)
Description
Approved Downdraft Models
Page 4 of 5
GUIDE
(A) Maximum
36" (91.4 cm)
42" (106.7 cm)
1
15" min.
(38.1 cm)
See Note 3
MRV3015S
MRV3615S
Ph. 800.793.0093