Cabinet And Countertop Layout - Dacor Heritage Series Installation Instructions Manual

Hide thumbs Also See for Heritage Series:
Table of Contents

Advertisement

Cabinet and Countertop Layout

• To reduce risk of burn injury from reaching over a hot appliance, do not
hang cabinets above the cooktop.
• Failure to meet or exceed the max/min dimensions and clearances in
this manual may cause a fire hazard.
• Follow the countertop manufacturer's instructions regarding minimum
corner radius, use of heat-reflective tape, corner reinforcement, etc.
• Carefully check the cooktop location site. For best perfor-
mance, the cooktop should be near drafts from open doors/
windows, and heating/air-conditioning vents.
• This appliance is to be used with a suitable vent hood or
approved Dacor downdraft vent.
Minimum Clearances Around the Cooktop
This section consists of illustrations/notes/tables for clearance
allowances. All tolerances: +1/16" -0" unless otherwise noted.
3
13" max.
(33.0 cm)
30" min.
Combustible
(76.2 cm)
surface to rear
See cutout
dimensions
1
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate).
2
If installing with an overhead range hood, check the hood
specifications for minimum required clearances.
3
This specification does not apply for cabinets located
greater than a horizontal distance of 5 1/2" (14.0 cm) from
edge of cooktop. Allow 6 7/8" (17.5 cm) from cutout edge.
Model
(A) Minimum
HCT305G
30" (76.2 cm)
HCT365G
36" (91.4 cm)
Installation Specifications
WARNING
A
18" min.
(45.7 cm)
1, 2
1 5/8" min.
(4.1 cm)
See cutout
dimensions
(A) Recommended
36" (91.4 cm)
42" (106.7 cm)
* Allows for clearance between hold down brackets
• Allow at least 1/4" (6 mm) clearance from the bottom of the
cooktop chassis to all combustible surfaces (incl. the top edge
of a drawer).
Model
HCT305G
HCT365G
• The gas-supply piping, gas shut-off valve, and the electrical
outlet must be located so as not to impede cooktop installa-
tion. If installing an appliance below the cooktop, allow for
gas/electrical routing behind it.
Installation must allow:
• access to the gas shut-off valve and regulator
• access to the electrical outlet; the 42" (106.7 cm) power cord
must be able to reach its intended outlet.
• access to the cooktop bottom for service/inspection.
1, 3
• space in the cabinet for the cooktop hold-down brackets.
Do not install a fixed shelf below the cooktop.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only the approved
Dacor downdraft model numbers below.
Cooktop Model
HCT305G
HCT365G
1/4" (6 mm)
mimimum clearance
to combustible
B
surfaces
Under-Cabinet Clearances
(B) Minimum
29 1/4" (74.3 cm)
35 1/4" (89.5 cm)
Approved Downdraft
ERV3015
ERV3615
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heritage hct365gHeritage hct305g